Procedure
➮ Remove at least 7 mm of the optical fiber cable's plastic sheat (diameter 2.2 mm);
see figure, [1]). Take care that the dismantled end of the optical fiber cable is not
contaminated. If necessary, clean it gently with a dry tissue paper.
➮ Insert the dismantled optical fiber cable carefully as shown in the figure into the
connector. The polymer fiber of 1 mm should stand out from the connector about 1
to 2 mm (see figure, [2]).
➮ Press the clip of connector so that the polymer fiber is hold in the connector. The
connector and the clip must interlock audibly (see figure, [3]).
➮ Insert the connector with the optical fiber cable into a polishing disk and grind the
outstanding end of the fiber by means of a polishing sheet on an even surface
(e.g. glass sheet), see figure, [4]). Remove grinding residues.
You can order the following materials at SIEB & MEYER:
Article
SIEB & MEYER article number
Polishing disk for optical fiber cables
47000001
Dismantling tool for optical fiber cables
47000002
Grinding paper
47000003
8.8
X29 – Analog Inputs/Outputs
9-pole male submin D connector
X29
Pin
I/O
Name
Meaning
1
I
Reference value (-) Differential amplifier input, reference point for pin 2
2
I
Reference value (+) Differential amplifier input, reference point for pin 1
3
I
Active load (-)
Differential amplifier input, reference point for pin 4
4
I
Active load (+)
Differential amplifier input, reference point for pin 3
5
I/O
GND
Ground
6
O
AOUT0
Programmable analog output 1 (0 V – 10 V)
7
O
AOUT1
Programmable analog output 2 (0 V – 10 V)
8
O
V
MEAS
5.3 V supply voltage
9
O
+10 V
ref
Reference voltage for analog inputs, I
max
= 20 mA
Stud bolt flange: max. tightening torque = 0.7 Nm
Related topics
Connection examples: "X29 – Analog Inputs/Outputs", page 52
Connectors
W
36
FC2 - Frequency converter 02192100xy
8
Summary of Contents for FC2
Page 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Page 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Page 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Page 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Page 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Page 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Page 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...