8.12
X33 – Outputs for Spindle Selection
25-pole male submin D connector
X33
Pin
I/O
Name
Meaning
1
O
OUT8
Spindle selection 1
2
O
OUT9
Spindle selection 2
3
O
OUT10
Spindle selection 3
4
O
OUT11
Spindle selection 4
5
O
OUT12
Spindle selection 5
6
O
OUT13
Spindle selection 6
7
O
OUT14
Spindle selection 7
8
O
OUT15
Spindle selection 8
9
O
+24V
10
O
+24V
11
I/O
GND
Ground
12
I/O
GND
Ground
13
I/O
GND
Ground
14
O
OUT16
Spindle selection 9
15
O
OUT17
Spindle selection 10
16
O
OUT18
Spindle selection 11
17
O
OUT19
Spindle selection 12
18
n.c.
19
n.c.
20
n.c.
21
n.c.
22
n.c.
23
n.c.
24
+24 V_ext
Voltage supply for outputs
25
+24 V_ext
Voltage supply for outputs
Stud bolt flange: max. tightening torque = 0.7 Nm
The spindle selection is active when an input voltage of 24 V is applied.
When a spindle is selected the corresponding output at the connector X33 is set for
feedback. This output can be evaluated by the CNC or it controls the motor contactor.
A modified spindle selection becomes active when
1. “Switch on” is deactivated and
2. “Switch on” is activated again.
Related topics
Connection example: "X33 – Outputs for Spindle Selection", page 56
W
Connectors
FC2 - Frequency converter 02192100xy
45
8
Summary of Contents for FC2
Page 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Page 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Page 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Page 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Page 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Page 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Page 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...