7.11
X19 – COM1 / Operating Terminal
9-pole male submin D connector
X19
Pin
I/O
Name
Meaning
1
O
VCC
5.3 V (power supply for optional oper‐
ating terminal, short-circuit proof)
2
I
RX
Receive data
3
O
TX
Transmit data
4
I/O
CAN_L
CAN_L
5
I/O
GND
Ground
6
I
RX2
Receive data 2
7
O
TX2
Transmit data 2
8
I/O
CAN_H
CAN_H
9
I/O
GND
Ground
Stud bolt flange: max. tightening torque = 0.7 Nm
Related topics
Connection examples: "X19 – Bus Connection", page 73
7.12
X26/ X27 – SERVOLINK 4
SERVOLINK 4: optical input (X26) and optical output (X27)
The fiber optic connectors for SERVOLINK 4 are located at the bottom side of the
device.
Connector
SIEB & MEYER article number
Inputs (black)
12540102
12540103
Outputs (gray or white)
12540202
12540203
Cable connector
(TOSLINK F05)
32022900
NOTICE
Risk of cable damage
If you pull the optical fiber cable with its connector too fast out of the connector, the
cable may be damaged.
When unplugging the cable, hold the fiber optic connector and pull the cable care‐
fully out of the connector.
Related topics
Connection example: "X26/X27 – SERVOLINK", page 75
Connector Pin Assignment
W
48
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
7
Summary of Contents for SD2S 0362249xy
Page 4: ...Chapter Overview W 4 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 8: ...Content W 8 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 12: ...About this Manual W 12 Drive System SD2S Hardware Description 0362X49xy 0362129xy 1...
Page 16: ...General Information W 16 Drive System SD2S Hardware Description 0362X49xy 0362129xy 2...
Page 30: ...Drive Amplifier SD2S W 30 Drive System SD2S Hardware Description 0362X49xy 0362129xy 5...
Page 54: ...Connector Pin Assignment W 54 Drive System SD2S Hardware Description 0362X49xy 0362129xy 7...
Page 80: ...Setup W 80 Drive System SD2S Hardware Description 0362X49xy 0362129xy 9...