8.11
X45 – Motor Phases
Ground the motor housing in the machine!
DANGER
Dangerous shock currents
Earthing and shielding measures are required to protect devices and persons. To
ensure the safety of the operator earthing must be carried out with low impedance.
With respect to the ground connection one of the following actions must be done:
▶
connect the motor housing to the ground of the machine or
▶
connect the ground terminal of the motor connector to the central ground point
of the machine.
Consider the following with regard to shielding: Always use shielded motor cables.
Voice coil motors are generally connected via the motor phases U and W.
The current parameters of voice coil motors can only be indicated as sine
peak amplitudes (A
p
), not as RMS values (A
rms
).
Connection Examples
W
76
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
8