Code
Error message
Error reaction
Possible reason
9
Communication error
between DSP and safety
controller
9
Safety function SFM/SLOF:
communication between DSP and
safety controller is disturbed
E47
(0x52F)
(1327
d)
Drive parameters not activated
Power output stage can not be
activated.
▶
Drive start is not acknowledged by
master yet (configurable by para‐
meters in software).
E55
(0x737)
(1847
d)
Firmware stopped by ESC
Device stops in BIOS.
▶
During boot-up, the device received
an ESC sequence at the serial
interface.
E56
(0x738)
(1848
d)
Device configuration
Device stops in BIOS.
▶
During boot-up the device detected
that hardware, firmware parame‐
ters and logic are not consistent; A
detailed error description is
received by a parameter download.
E57
(0x739)
(1849
d)
Faulty or no firmware
Device stops in BIOS.
▶
During boot-up the device detected
no firmware or a faulty firmware.
E58
(0x73A)
(1850
d)
FPGA watchdog triggered
Device stops in BIOS.
▶
FPGA process monitoring has
been triggered; Please contact
SIEB & MEYER.
E59
(0x73B)
(1851
d)
No drive parameters loaded
Device stops in BIOS.
▶
Device is not parameterized (status
of delivery).
E60
(0x73C)
(1852
d)
Drive parameters incorrect
Device stops in BIOS.
▶
Parameter set of the device is not
valid (CRC error).
E61
(0x73D)
(1853
d)
Logic coding missing or incorrect
Device stops in BIOS.
▶
Logic programming of the device is
not valid.
E62
(0x73E)
(1854
d)
Error in electronic type plate
Device stops in BIOS.
▶
Type plate is not programmed or
faulty;
Please
contact
SIEB & MEYER.
(1)
For servo motors with commutation via an incremental motor measuring system, the warning W17
“Unknown commutation angle ” is signaled. After a restart of the device, the phasing of the motor measuring
system starts automatically (magnetic alignment).
10.2.3
List of Warning Messages
Warning messages are not displayed on the device display. They can only be seen in
the software
drivemaster2 via “Diagnosis
ÿ
Errors and warnings”.
Code
Description
W00
Digital input 'Quick stop' active
W01
Digital input 'Positive limit switch' active
W02
Digital input 'Negative limit switch' active
W03
Voltage of mains supply not OK
W04
Power output stage load greater than parameterized warning threshold W04 (power output
stage I²t)
W05
Motor load greater than parameterized warning threshold W05 (motor I²t)
W06
Power output stage temperature greater than parameterized warning threshold W06
W07
Motor temperature greater than parameterized warning threshold W07
W08
DC link voltage greater than parameterized warning threshold W08
W
Status Display and Error Messages
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
87
10
Summary of Contents for SD2S 0362249xy
Page 4: ...Chapter Overview W 4 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 8: ...Content W 8 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 12: ...About this Manual W 12 Drive System SD2S Hardware Description 0362X49xy 0362129xy 1...
Page 16: ...General Information W 16 Drive System SD2S Hardware Description 0362X49xy 0362129xy 2...
Page 30: ...Drive Amplifier SD2S W 30 Drive System SD2S Hardware Description 0362X49xy 0362129xy 5...
Page 54: ...Connector Pin Assignment W 54 Drive System SD2S Hardware Description 0362X49xy 0362129xy 7...
Page 80: ...Setup W 80 Drive System SD2S Hardware Description 0362X49xy 0362129xy 9...