Related topics
Chapter "Motor Cable", page 92
8.12
Shielding of the Motor Cable
For the operation of SD2S the motor cable needs to be shielded. Depending on the
device and application more shielding measures might be required.
The following examples explain how to connect the motor cable shield to the device
housing using a shield connection clamp by Phoenix (see
➮ Remove the insulation of the motor cable on a length of approximately 30 mm in
the place it will be fixed in the terminal.
➮ Place the motor cable between the slot holes at the bottom of the device.
➮ Put the terminal over the cable into the slot holes.
➮ Push the terminal to the back so that the lugs lock in the circular holes.
➮ Fix the cable using the knurled screw.
─
SK 14: max. tightening torque = 0.8 Nm
8.13
X63 – External Ballast Resistor
W
Connection Examples
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
77
8