Original operating instructions AEROLIFE
08.2016
15
Commissioning
Electrically operated unit.
Risk of fatal injury from electric shock or fire.
›
The AEROLIFE is connected directly to the 230-V AC mains power supply. However, the voltage is transformed to 12 V
low voltage in the unit. In case of overload, a safety device (thermal overload protection) in the transformer disconnects
the unit from 230 V AC mains power supply and automatically switches on again when the overload has been rectified.
›
A safety switch is also integrated for maintenance purposes. If the front panel is removed, the safety switch cuts off the
supply voltage.
To prevent personal injury or damage to property, always comply with the following instructions:
›
The power supply terminals supply 230 V AC even when the front panel has been removed.
›
Do not remove the cover of the connecting clamps behind the top housing unit.
Following the successful installation and electrical connection of the AEROLIFE, the unit can be commissioned.
• The Euro plug of the mains cable must be properly connected to the 230 V AC mains power supply via a power socket. If
the unit has been permanently connected to the 230 V AC mains power supply, the safety device belonging to this
electrical circuit must be switched on.
• Remove any transport and mounting aids prior to the commissioning.
Operation
›
Open the closing flaps (
a
), before the AEROLIFE is
switched on.
›
Shut the closing flaps (
b
), before the AEROLIFE is
switched off for a longer period.
a
b
›
Switch the unit on/off or set the required air flow by briefly pressing the button.
Switch sequence
Unit is switched off
Air flow level 1
Air flow level 2
Air flow level 3
Unit is switched off
...