background image

Installation and operating instructions 

AEROMAT 150

Last update: 08.2014

7

Function and operation

With SIEGENIA AEROMAT 150 sound absorbing ventilators, you can still ventilate with closed windows, safely, economical-
ly, without draughts and without outside noise.

Pressure differential operation (Type DD / DK)

AEROMAT 150 Type DD / DK is a sound absorbing ventilator based on pressure differential. A rotary knob allows you to 
continuously adjust the required airflow.
There is a pressure differential between indoor and outdoor air. The room is ventilated as the indoor and outdoor air 
pressures are equalised. Normally, air flows from outside into the room. The air flow into the room varies as the pressure 
created by the wind changes with the weather.

Type DD

The rotary knob allows you to open and close the locking plate. You may continuously adjust the required airflow between 
both end positions of the rotary knobs.

1

2

Type DK 

(with 5-wired connecting cable)

Opening and closing of the locking plate only via external switches, e.g. AF1 or triggering via external units.

Öffnen

Schliessen

Ventilator operation (Type AW4)

• 

The AEROMAT 150 Type AW4 is a ventilator with axial blower. 

Type AW4 allows you to reinforce the air flow with an additional 2-step radial blower. The blower is automatically turned on 
with the selected power level when the locking plate opens, and it is turned off when the locking plate closes. 
An indicator lamp indicates the blower operation.

If an object blocks the closing operation in an opening of the front panel, the locking plate opens again immediately. The unit 
repeats the closing operation until the object has been removed.

Locking plate

Rotary knob

Control 
lamp

Summary of Contents for AEROMAT 150

Page 1: ...Install ation and operating instructions AEROMAT 150 Sound absorbing ventilator Window hardware Door hardware Sliding door hardware Ventil ation technology Building technology Ventil ation technology ...

Page 2: ......

Page 3: ...tructions AEROMAT 150 Last update 08 2014 3 Contents Important information 4 Intended use 4 Safety notices 4 Installation 5 Mains supply 6 Function and operation 7 Cleaning 8 Accessories 9 Technical data 9 Dimensions 9 Liability 10 ...

Page 4: ...ed specialists with training and practice in the repair of ventilation units Any use of this product that is not in accordance with its intended use or any adaptation of or modification to the product and its associated components for which the express consent of SIEGENIA has not been obtained is strictly prohibited SIEGENIA accepts no liability whatsoever for any material losses or injury to peop...

Page 5: ...on sequence 1 Carefully remove AEROMAT 150 from the packaging We recommend placing the unit on a soft surface e g cardboard or blanket during installation 2 Type DD Close the locking plate on the front to prevent contamination e g dust from entering the unit during installati on 3 Install the AEROMAT 150 in its intended installation position and seal it in accordance with the installation directiv...

Page 6: ...the 230 V AC mains power supply a mains isolator must be installed by the customer Wire the circuit according to this circuit diagram Connection Type DK Connection Type AW4 PE 1 2 3 5 4 6 S1 PE N L1 PE 1 2 3 5 4 6 PE N L1 S1 S2 S3 S4 1 2 3 5 4 Switch assignment Switch assignment Switch position S1 Opening and closing of the locking plate S1 Turn system on off open unit is off S2 Opening and closin...

Page 7: ...r Type DD The rotary knob allows you to open and close the locking plate You may continuously adjust the required airflow between both end positions of the rotary knobs 1 2 Type DK with 5 wired connecting cable Opening and closing of the locking plate only via external switches e g AF1 or triggering via external units Öffnen Schliessen Ventilator operation Type AW4 The AEROMAT 150 Type AW4 is a ve...

Page 8: ...gy you may also operate the Type AW4 as pressure differential ventilator without blower To do so open the locking plate and then turn off the ventilator Cleaning Cleaning the unit Switch off all poles of the feeder Only clean the AEROMAT 150 as to where the unit is accessible safely Observe the safety regulations for ladders steps works in particular heights etc If required clean the outer parts o...

Page 9: ...dB 51 dB 51 dB Air throughput measured at 10 Pa pressure differential 1 200 mm ventilator length and with weather grille 910 CW 1 approx 60 m3 h approx 60 m3 h Air throughput with 1 blower and 1 200 mm ventilator length Level 1 70 m3 h Level 2 120 m3 h Electrical connection 230 V 0 01 A 230 V max 0 17 A Protection class I Power consumption Level 1 5 W Level 2 32 W U value calculated in accordance ...

Page 10: ...smantled and the defect is due to the changes made Exclusion of liability The product and its components are subject to stringent quality controls As a result they function reliably and safely when used correctly Our liability for consequential losses and or claims for damages is excluded except in the case of wilful misconduct or gross negligence or where we are responsible for injury to life lim...

Page 11: ......

Page 12: ... 9 2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4477700 Russia Phone 7 495 7211762 South Korea Phone 82 31 7985590 Switzerland Phone 41 33 3461010 Turkey Phone 90 216 5934151 Ukraine Phone 380 44 4637979 You can find address details for our internat...

Reviews: