Electro-mechanical systems
Assembly instructions
A-opener 2.2
09.2019
12
/20
H39.ELEKS011EN-00
5.3.2
Via the analogue connection
To obtain a connection via the analogue connection, establish a plug connection with the KFV cable.
KFV cable
Cable identifi
-
cation
Band colour
Cable colour
Connection A-opener
Function
0
1
4
7
+
-
0
Black
grey
-
-
1
Brown
Yellow
-
-
4
Yellow
Green
4: input
External unlocking signal
7
Violet
Pink
-
-
+
Red
White
2: + 24VDC
Operating voltage (+) 24 V DC
-
Blue
Brown
3: - GND
Operating voltage (-)
White
Blue
-
-
+
-
4
1
2
+
-
4
f
Establish a plug connection with
the cable (type F or E) [1] and
the green PTR plug [2].
f
Tighten the screws of the PTR
plug by hand so that the wires
of the cable will not be able to
loosen themselves.
Check the firm seating.
+
-
4
1
+
-
4
f
Insert the green PTR plug
[1] into the connection with
the designation 2 to 4 of the
A-opener.
f
Route the cable and connect it
to a power supply and optionally
to an analogue access control
system (see chapter 4.2).