6.4
Troubleshooting
6.4.1
Functional disorder of the lever handle
If the lever handle does not return to its original posi
-
tion by itself, there is a functional disorder.
f
Check the routed pocket for dimensional accuracy.
f
Check that the lever handle is correctly seated.
f
Check that the door hardware is correctly seated.
If the lever handle does not return to its original posi
-
tion by itself, the multi-point lock must be checked by
KFV.
6.4.2
Functional disorder of the profile cylinder
f
If you cannot remove the key, dismount the profile
cylinder and check it for functional disorders.
f
If the profile cylinder does not function faultlessly,
replace the cylinder and repeat the test step.
If the profile cylinder functions faultlessly, there is a
mechanical disorder in the multi-point lock.
f
Check whether the locking elements run smoothly
into the frame parts. If this is not the case, adjust
the frame parts.