15
/20
Assembly instructions
Electro-mechanical systems
A-opener 2.2
15
/20
09.2019
H39.ELEKS011EN-00
6.5
Technical specifications
Environmental conditions
Ambient temperature range in the door (according to DIN
EN 14846 class K,M,L,N,P)
T
UM
- 25 °C to + 70 °C
Relative humidity
20% to 80% (non-condensing)
Protection class
IP 40
Electrical data
Operating voltage
U
B
24 V DC (19 V DC to 32 V DC)
Operating current standby / standby
I
ST
Type 30 mA
Operating current for motor control
I
B
Type 500 mA (max. 1000 mA)
Reverse polarity protection
U
Verp
- 50 V
Input signal terminal 4
Release On
U
KL4.ON
> 7.0 V DC
Release Off
U
KL4.OFF
< 4.0 DC V
Internal with Pulldown resistance
R
Pulldown
4.7 kΩ
Dimensions
Dimensions
W x L x D
16 mm, 252 mm, 49 mm + secondary sash thickness
Cable lengths
Cable length at 0.14 mm²
LIYCY
≤ 24 m
Cable length at 0.5 mm²
LIYCY
≤ 50 m
Summary of Contents for KFV A-Opener 2.2