Electro-mechanical systems

Assembly instructions

A-opener 2.2

09.2019

4/20

H39.ELEKS011EN-00

Introduction

Please read these instructions carefully before you 

begin the assembly work. Follow the notes in Chapter 2 

"Safety", in order to prevent personal injury or func

-

tional disorders.
These instructions are an integral part of the A-opener 

2.2 and must be accessible to the specialist personnel 

at all times.

1.1 

Producer and service

KFV Karl Fliether GmbH & Co. KG 

 

A company of the SIEGENIA GROUP

 

Siemensstraße 10 

 

42551 Velbert
Tel.: +49 2051 278-0 

 

Fax: +49 2051 278-167 

 

E-mail: info@kfv.de
Please contact your contractual partner in case of com

-

plaints or service requirement.

1.2 

Target group of this documentation

This documentation is intended for use by specialists 

only. All work described in this document is to be per

-

formed only by experienced professionals with train

-

ing and practice in the assembly, commissioning and 

maintenance of electromechanical components and 

multi-point locks. 
All work on a 230 V AC mains power supply may only 

be performed by a qualified electrician.

1.3 

Intended use

• 

In combination with automatic multi-point locking, 

the A-opener 2.2 enables motorised unlocking and 

is suitable for installation in timber, aluminium, steel 

and PVC entrance doors.

• 

The A-opener 2.2 may only be used

– 

with cylinder locks with a rigid catch in which 

the catch is locked in a key withdrawal position 

inside the range of - 30° to + 30°

– 

with cylinder locks with a non-restrictive catch in 

which the catch can always be freely turned

– 

in vertical installation

– 

in a technically sound condition

– 

in conjunction with KFV products and accessories

1.4 

Improper use

• 

The A-opener 2.2 must not be used in combination 

with an automatic multi-point locking system

– 

for escape doors in accordance with EN 179 or 

EN 1125

–  in doors for wet rooms or rooms in which the air 

contains aggressive or corrosive components

• 

The A-opener 2.2 and the automatic multi-point 

lock must not be interfered with or modified.

1.5 

Maintenance and service notes

Never use cleaning agents that are aggressive or con

-

tain solvents. This could damage the surfaces of the 

components.

1.6 

Installation conditions and requirements

Local building laws and regulations must be observed 

before and during installation. 

1.7 

Dimensions

All measurements are given in mm.

1.8 

Symbols used

The following icons are used in this document:

General warning symbol

Useful information or advice

1.9 

Other types of indicators

Below is a list of symbols used in these instructions and 

their meanings:

• 

Items of text following this marker are found in lists.

– 

Items of text following this marker are found in 

subordinate lists.

 

f

Items of text with this marking in front of them are 

instructions that must be followed in the specified 

order.

Cross reference

()  A cross reference in the flow text is enclosed by 

brackets.

Summary of Contents for KFV A-Opener 2.2

Page 1: ...ASSEMBLY INSTRUCTIONS KFV A opener 2 2 Electro mechanical systems Comfort systems Door systems Window systems...

Page 2: ......

Page 3: ...Connections and operating elements 7 4 2 Cable and wiring diagram 8 5 INSTALLATION 10 5 1 Installing the A opener 10 5 2 Milling the door leaf 10 5 3 Routing and connecting cables 11 5 3 1 Via the SI...

Page 4: ...ks with a rigid catch in which the catch is locked in a key withdrawal position inside the range of 30 to 30 with cylinder locks with a non restrictive catch in which the catch can always be freely tu...

Page 5: ...n designates warning notices that warn of personal injury The type and source of the hazard defines the cause of the hazard The potential consequences of non obser vation of warning notices are e g da...

Page 6: ...onditions must be observed before and during installation Observe the specified positions and sizes for all milling and drilling dimensions within the defined tolerances Install the A opener 2 2 in ac...

Page 7: ...e 24 V DC white 2 Analogue connection Terminal 2 output supply voltage 24 V DC Terminal 3 output supply voltage Terminal 4 input for external unlocking signal at 24 V DC 1 seconds opening process 3 Bu...

Page 8: ...e 230 V AC mains power supply must be carried out in compliance with the current German VDE regula tions e g VDE 0100 and any relevant country specific requirements A opener via SI BUS connection A op...

Page 9: ...2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 SI BUS system 1 1s 1s V L N PE V A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 1 2 3...

Page 10: ...1 Installing the A opener 3 x M4x11 The A opener 2 2 is supplied unas sembled as standard f f Screw the A opener to a suitable KFV multi point lock using the three screws included in the delivery T 1...

Page 11: ...urr all holes for the cable routing Do not route cables over sharp edges File or line any sharp edges Route cables without kinking A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V D...

Page 12: ...l unlocking signal 7 Violet Pink Red White 2 24VDC Operating voltage 24 V DC Blue Brown 3 GND Operating voltage White Blue 4 1 2 4 f f Establish a plug connection with the cable type F or E 1 and the...

Page 13: ...he key in the locking direction until the main deadbolt extends The lever handle is blocked the child proof lock is active f f Turn the key in the unlocking direction until the main deadbolt retracts...

Page 14: ...rrectly seated If the lever handle does not return to its original posi tion by itself the multi point lock must be checked by KFV 6 4 2 Functional disorder of the profile cylinder f f If you cannot r...

Page 15: ...P 40 Electrical data Operating voltage UB 24 V DC 19 V DC to 32 V DC Operating current standby standby IST Type 30 mA Operating current for motor control IB Type 500 mA max 1000 mA Reverse polarity pr...

Page 16: ...t and Certification Authority test report identification number FS 1708 336996 001 The incomplete machine may only be commissioned if it has been ascertained if required that the machine into which it...

Page 17: ...17 20 Assembly instructions Electro mechanical systems A opener 2 2 17 20 09 2019 H39 ELEKS011EN 00 6 7 Test report Electromagnetic compatibility...

Page 18: ...Electro mechanical systems Assembly instructions A opener 2 2 09 2019 18 20 H39 ELEKS011EN 00...

Page 19: ......

Page 20: ...www siegenia com H39 ELEKS011EN 00...

Reviews: