Assembly instructions

Electro-mechanical systems

A-opener 2.2

5

/20

09.2019

H39.ELEKS011EN-00

1.10 

Applicable documents

For the installation of the A-opener 2.2, it is essential 

to observe all assembly and operating instructions that 

are enclosed with other (optional) components.

1.11 

Appropriate disposal

Electrical devices should not be disposed of as house

-

hold waste. Bring the device, accessories and packaging 

to an environmentally-friendly recycling facility.

Safety

• 

All work on the 230 V AC mains power supply 

must be carried out in compliance with the current 

German VDE regulations (e.g., VDE 0100) and any 

relevant country-specific requirements.

• 

All-pole safety isolation should be used when rout

-

ing the network connection cable on-site.

• 

Any modifications to the A-opener 2.2 are prohibit

-

ed. 

• 

Wiring the unit incorrectly can irreparably damage 

its electronic components.

2.1 

Structure of the warning notes

The warning notes in these instructions 

• 

when observed, provide protection against potential 

personal injury and material damage, 

• 

classify the level of danger by the signal word,

• 

designate the danger of personal injury via the 

hazard sign,

• 

define the type and source of danger,

• 

show measures to prevent hazards and prohibit 

specific behaviour.

The warning notes are set up according to the following 

principle:

SIGNAL WORD

Type and source of danger

Explanation of the type and source of danger

• 

Measures for the prevention of the danger

The hazard sign designates warning notices that warn 

of personal injury.
The type and source of the hazard defines the cause of 

the hazard. The potential consequences of non-obser

-

vation of warning notices are e.g. danger to life due to 

electric shock.
Under measures, actions are listed that must be carried 

out for the prevention of hazards or which are prohibit

-

ed for the prevention of a hazard. 

2.2 

Warning notes used

DANGER

The signal word "Danger" designates an immediately 

threatening danger. If this hazard is not prevented, it 

leads to death or severe injuries.

WARNING

The signal word "Warning" designates a potential 

hazard. If this hazard is not prevented, it could lead to 

death or severe injuries.

CAUTION

The signal word "Caution" designates a potentially 

hazardous situation. If this hazardous situation is not 

prevented, it could lead to minor or moderate injuries.

NOTICE

The signal word "Note" defines actions for the pre

-

vention of material damage. The observation of these 

notes prevents damage to the components.

Information, advice etc.

This symbol indicates special features and designates 

facts that require increased attention.

2.3 

Warning notes

WARNING

Risk of fatal injury from electric shock and short circuit

Wrong connection of the A-opener

• 

All-pole safety isolation should be used when routing 

the network connection cable on-site.

• 

All work on the 230 V AC mains power supply must be 

carried out in compliance with the current German VDE 

regulations (e.g., VDE 0100) and any relevant coun

-

try-specific requirements.

If energy-carrying cables are routed in parallel to data 

cables (ISDN, DSL, etc.), this could lead to interference e.g. 

in the speed of the data transmission.

Summary of Contents for KFV A-Opener 2.2

Page 1: ...ASSEMBLY INSTRUCTIONS KFV A opener 2 2 Electro mechanical systems Comfort systems Door systems Window systems...

Page 2: ......

Page 3: ...Connections and operating elements 7 4 2 Cable and wiring diagram 8 5 INSTALLATION 10 5 1 Installing the A opener 10 5 2 Milling the door leaf 10 5 3 Routing and connecting cables 11 5 3 1 Via the SI...

Page 4: ...ks with a rigid catch in which the catch is locked in a key withdrawal position inside the range of 30 to 30 with cylinder locks with a non restrictive catch in which the catch can always be freely tu...

Page 5: ...n designates warning notices that warn of personal injury The type and source of the hazard defines the cause of the hazard The potential consequences of non obser vation of warning notices are e g da...

Page 6: ...onditions must be observed before and during installation Observe the specified positions and sizes for all milling and drilling dimensions within the defined tolerances Install the A opener 2 2 in ac...

Page 7: ...e 24 V DC white 2 Analogue connection Terminal 2 output supply voltage 24 V DC Terminal 3 output supply voltage Terminal 4 input for external unlocking signal at 24 V DC 1 seconds opening process 3 Bu...

Page 8: ...e 230 V AC mains power supply must be carried out in compliance with the current German VDE regula tions e g VDE 0100 and any relevant country specific requirements A opener via SI BUS connection A op...

Page 9: ...2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 SI BUS system 1 1s 1s V L N PE V A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 1 2 3...

Page 10: ...1 Installing the A opener 3 x M4x11 The A opener 2 2 is supplied unas sembled as standard f f Screw the A opener to a suitable KFV multi point lock using the three screws included in the delivery T 1...

Page 11: ...urr all holes for the cable routing Do not route cables over sharp edges File or line any sharp edges Route cables without kinking A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V D...

Page 12: ...l unlocking signal 7 Violet Pink Red White 2 24VDC Operating voltage 24 V DC Blue Brown 3 GND Operating voltage White Blue 4 1 2 4 f f Establish a plug connection with the cable type F or E 1 and the...

Page 13: ...he key in the locking direction until the main deadbolt extends The lever handle is blocked the child proof lock is active f f Turn the key in the unlocking direction until the main deadbolt retracts...

Page 14: ...rrectly seated If the lever handle does not return to its original posi tion by itself the multi point lock must be checked by KFV 6 4 2 Functional disorder of the profile cylinder f f If you cannot r...

Page 15: ...P 40 Electrical data Operating voltage UB 24 V DC 19 V DC to 32 V DC Operating current standby standby IST Type 30 mA Operating current for motor control IB Type 500 mA max 1000 mA Reverse polarity pr...

Page 16: ...t and Certification Authority test report identification number FS 1708 336996 001 The incomplete machine may only be commissioned if it has been ascertained if required that the machine into which it...

Page 17: ...17 20 Assembly instructions Electro mechanical systems A opener 2 2 17 20 09 2019 H39 ELEKS011EN 00 6 7 Test report Electromagnetic compatibility...

Page 18: ...Electro mechanical systems Assembly instructions A opener 2 2 09 2019 18 20 H39 ELEKS011EN 00...

Page 19: ......

Page 20: ...www siegenia com H39 ELEKS011EN 00...

Reviews: