5.3
Routing and connecting cables
Various cable types are available for establishing a connection from the power supply to the A-opener and an
access control system.
Only use shielded cables in order to prevent interferences, which have an effect on the KFV multi-point lock with A-opener 2.2, or originate from
the KFV multi-point lock with A-opener 2.2.
Only use the shielded original KFV cable. See: product catalogue KFV GENIUS and A-opener.
Deburr all holes for the cable routing.
Do not route cables over sharp edges. File or line any sharp edges.
Route cables without kinking.
A
SI-Bus
Siemensstr
. 10
D-42551 V
elbert
A-OPENER 2.2
SN:
R1:
R2:
R3:
24V DC
GND
24V DC GND
Input
B C D
2 3 4
Always route the cable to the A-open
-
er 2.2 in a loop to prevent any ingress
water from running into the connec
-
tions of the A-opener.
5.3.1
Via the SI-BUS connection
Use only the SI-BUS cable from KFV intended for this purpose to establish a connection via the SI-BUS.
1
2
3
SI-BUS system
f
Insert the green PTR plug [1] of
the SI-BUS adapter cable [2] into
the connection with the desig
-
nation A to D.
f
Connect the plug [3] of the SI-
BUS adapter cable to the SI-BUS
system and route the cable (see
chapter 4.2).