Target group of this documentation
This documentation is intended to be used by specialists only. All work described in this document is to be performed by
experienced professionals with training and practice in the assembly, installation and maintenance of the GENIUS door
lock and its individual components. Safe and proper assembly of this electronic door lock is not possible without expert
knowledge.
Intended use
•
The GENIUS door lock is a special lock for automatically locking and unlocking doors.
•
It is suitable for installation in timber, aluminium, steel and PVC entry doors for residential and public buildings.
•
All assembly and electrical installation work must be carried out according to our assembly and installation instruc-
tions. Wiring the unit incorrectly can irreparably damage its electronic components.
•
The GENIUS door lock must be used with a free-running cylinder compliant with the German standard DIN 18252.
Alternatively a thumbturn cylinder can be used, but it should be noted that this will result in a loss of power at the
locking points.
•
The GENIUS door lock can be connected to an external access control system (e.g. wireless, transponder or finger-
print scanner system) via a voltage-free contact (switching time: min. 1 second).
•
Use the GENIUS door lock only when it is in a technically sound condition. Do not modify the unit's components in
any way.
•
Use the GENIUS door lock only with genuine KFV accessories.
Improper use
•
The GENIUS door lock must not be used with a cylinder with a fixed catch, as this will cause the main lock to jam
when the key is removed.
•
The GENIUS door lock must not be installed in moisture-prone areas or areas with a corrosive atmosphere (e.g. elect-
roplating shops).
•
The length of the cable between the power supply and the GENIUS door lock must not exceed 13 m.
Safety notes
•
Work on an 230 V AC mains power supply may only be performed by a qualified electrician.
•
All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regu-
lations (e.g. VDE 0100) and any relevant country-specific requirements.
•
All-pole safety isolation should be used when fitting the power lead on-site.
•
Some external access control systems available on the market transmit a brief "open" signal when the operating vol-
tage is switched on. This can mean that the GENIUS door lock will open the door following a power cut. If in doubt,
please contact the system manufacturer.
Where power supply cables are routed parallel to data cables (IDSN, DSL etc), interference can occur, eg: with
the data transfer speed.
Warning