12.2019
60/66
H48.HSKFS0023EN
PORTAL
PremiDoor 88
Sill installa on
HS
17 Sill
installa on
17.1 Fixing the sill installa on correctly
With weather bar mounted
Fix the sill installa on on the bo om edge of the
weather bar to the sealing plate.
Abb. 19: Sill installa on with weather bar
With threshold installed
Fix the sill installa on on the bo om edge of the
threshold to the sealing plate.
Abb. 20: Sill installa on with threshold
17.2 Reveal connec on
No special requirements need be taken into account
for the sealing in the reveal area for connec on heights
with 60 mm over the wear level.
In the bo om connec on area, the sealing must be
undertaken 60 mm over the wear level. The side
connec on must be resistant to driving rain and
windproof. In this area, the sealing must be dimension
X over the wear level.
Dimension X from wear level = upper edge
fi
nished
fl
oor
Country
X
Germany
150
Switzerland
120
Further country-speci
fi
c informa on is available on request.
X