01.2022
96/108
H48.HSKFS0031EN
PORTAL
PremiDoor 76,
PremiDoor 76 Lux
Locking monitoring system
HS
ø 6
3
4
Drill through hole ø
.6.mm.for.the.cable.bushing..in.the.
end cap ogf the threshold.
Lead.the.cable.out.of.the.threshold.from.the.side.
Loop.cable.20.cm.in.the.profile.
21.3.1
Adjustment and installation of the magnet clamp
Remove.the.steel.reinforcement.in.the.assembly.area.on.the.sliding.sash.
1
Ensure that the magnet adjustment is existent in the
magnet.clamp..The.screw.head.must.be.on.top..
Determine.the.adjustment.of.the.magnetic.clamp.
according.to.the.DIN.orientation.of.the.sliding.sash.
3
9
4
3x
4x25
*
*.optional
Position.of.magnet.clamp.on.the.sliding.sash...Bottom.
edge of magnet clamp 9 mm higher than upper edge of
running rail.
Screw the magnet clamp to the sliding sash according
to.the.DIN.orientation..Predrill.the.screw.holes