18
112202RE101_A_M
5 OPERATION
EN
Drive the tractor to the ditch or pit.
Position the drain-shaft arch in front of the
drain.
Secure the drain-shaft arch with the
ground anchor.
Lay/place the suction hose in the pit or
water tank. Connect the return hose for
the pressure regulator to the top of the
guide arm. The water ‘lubricates’ and
cleans the flushing hose.
Disengage the pressure regulator. Engage
the PTO.
Recommended speed for the pump is 350 – 370 rpm. Use the lowest possible speed necessary
to achieve the operating pressure of 30-35 bar.
Run the reel slowly to roll out the hose;
tighten the tension roller until the drive no
longer slips.
Reel out the hose carefully until the nozzle
is ±3 centimetres from the drain (lever 1).
Set the distance indicator to 0.