Important notes
Table A:
Cord Type
Size of Conductors
Maximum Current
in Cord
Rating of Unit
SJT
18 AWG
10 Amps
16 AWG
12 Amps
14 AWG
12 Amps
SVT
18 AWG
10 Amps
17 AWG
12 Amps
For units set at 115 V:
use a parallel blade, grounding type attachment plug rated 15 A, 125 V (Figure 2).
For units set at 230 V (domestic use):
use a tandem blade, grounding type attachment plug rated 15 A, 250 V (Figure 3).
Figure 2
Figure 3
For units set at 230 V (outside of the United States and Canada):
use a cord set consisting of a minimum AWG according to Table A and a grounding type
attachment plug rated 15 A, 250 V. The cord set should have the appropriate safety
approvals for the country in which the equipment will be installed and marked HAR.
A26361-K293-Z1-1-7619
11