134
RM300 C Models
U24801-J-Z146-2-7600
12
Technical data
12.4
Electrical characteristics, safety standards and
EMC data
Electrical characteristics
Standards met
Rated voltage (range)
100-120 V or 220–240 V (switchable)
Tolerance of the rated voltage
+6/-10 %
Rated frequency
50 Hz / 60 Hz
Rated current (total)
max. 2.2 A at 240 V
max. 2.6 A at 120 V
Rated current of outlet socket
120 V/3 A; 240 V/1,5 A
Heat rating (heat dissipation)
max. 300 W
Electrical safety
EN 60950, UL1950, CSA 950
Electromagnetic compatibility
(EMC data)
FCC Regulations, Part 15, Subpart B,
Class A
Authorization as per EC Guideline
89/339/EWG:
Noise emission
EN 55022 class B
Noise suppression
EN 50082-(2)
Ergonomics
ZH1 618
Licenses
GS; UL (USA);
c
UL(CND); CE Compliance