Combination Starters, Classes 17, 18, 25, 26 and 32

Starter Sizes 0 - 4

Replacement Parts and Instruction Guide

E87010-A0137-T003-A4

August 2020

Supersedes Issue of

June 2015

Siemens Industry, Inc. 3617 Parkway Ln, Peachtree Corners, GA 30092   www.usa.siemens.com

                                 A5E31166526A-003    

Hazardous voltage.

Will cause death, serious personal injury,

or property damage.

SIGNAL WORDS

The signal words 

“Danger”

,

“Warning” 

and

 “Caution”

used in this manual indicate the degree of hazard that 

may be encountered by the user.

These words are defined as below:   

Danger

 -   Indicates death, severe personal injury or   

  

property damage will result if proper  

 

   

precautions are not taken. 

Warning

 - Indicates death, severe personal injury, or  

 

property damage can result if proper  

 

 

precautions are not taken.   

Caution

 -   Indicates personal injury or property  

 

 

damage may result if proper precautions    

 

are  not taken.

Short-Circuit Explosion Hazard. Can cause death, serious 

personal injury, or property damage. Fully engage all 

door latches and spread ends of door hinge pins 

approximately 45 degrees before energizing equipment.

QUALIFIED PERSON

For the purpose of this manual and product labels a 

qualified person is one who is familiar with the installa-

tion, construction, operation, or maintenance of the 

equipment and the hazards involved. In addition this 

person has the following qualifications:

 

(a)   is trained and authorized to energize,   

        de-energize, clear, ground, and tag circuits  

 

        and equipment in accordance with established                                 

        safety practices.

(b)   is trained in the proper care and use of  

 

        protective equipment such as rubber gloves,    

        hard hat, safety glasses or face shields, flash  

 

        clothing, etc., in accordance with established 

        safety practices.

(c)    is trained in rendering first aid.

Always de-energize and ground the equipment before 

maintenance. Read and understand this manual before 

installing, operating or maintaining the equipment. 

Maintenance should be performed only by qualified 

personnel. The use of unauthorized parts in the repair of 

the equipment or tampering by unqualified personnel may 

result in dangerous conditions which may cause death or 

serious personal injury or equipment or property damage. 

Follow all safety instructions contained herein.

s

Summary of Contents for 17

Page 1: ...sult if proper precautions are not taken Warning Indicates death severe personal injury or property damage can result if proper precautions are not taken Caution Indicates personal injury or property damage may result if proper precautions are not taken Short Circuit Explosion Hazard Can cause death serious personal injury or property damage Fully engage all door latches and spread ends of door hi...

Page 2: ...itch Type Selection Disconnect Fuse Clip Ampere Rating 3 ED63A003 10 ED63A010 25 ED63A025 30 ED63A030 50 ED63A050 100 ED63A100 125 ED63A125 150 FXD63A150L B1 Disconnect Switch Handle and Mechanism Class 17 25 32 Enclosure Type 1 3R 4 4X 12 Disconnect Size Amps Enclosure Size Handle Assembly Only Handle Assembly Disc Mech 3 125 100 125 150 250 24 H x 11 W x 8 D 24 H x 20 W x 8 D 36 H x 24 W x 8 D A...

Page 3: ...th primary fusing KT_ _ 150 is 150VA with primary fusing E Motor Starter or Contactor See device label for appropriate replacement parts sheet F Auxiliary Contacts Not Shown Auxiliary Contacts Installed on contactor 1NO G10 1 49AB10 2NO G20 1 49AB20 3NO G30 1 49AB20 1 49AB10 4NO G40 1 49AB40 1NC G01 1 49AB01 2NC G02 2 49AB01 1NO 1NC G11 1 49AB11 1NO 2NC G12 1 49AB12 2NO 1NC G21 1 49AB21 2NO 2NC G2...

Page 4: ...link to the mechanism The retaining ring should not spin freely on the shaft after it is installed 8 No handle adjustment is required 9 Verify that the handle mechanism turns ON and OFF the circuit breaker 10 Verify that the door cannot be opened with the handle in the ON position 1 Remove the 2 screws from the connecting link 2 Use a 5 16 wrench to remove the two 1 4 20 screws and lock washers wh...

Page 5: ...en provided to mount a new circuit breaker if necessary 5 Install the new handle assembly onto the enclosure 6 Reinstall the two 1 4 20 screws and lock washers Make sure the handle housing is sealed against the enclosure flange as this prevents the entry of moisture 7 Reinstall the two screws that connect the handle link to the pivot assembly 8 No handle adjustment is required 9 Verify that the ha...

Page 6: ...ed to access the mounting screws 4 Hardware has been provided to mount a new circuit breaker if necessary 5 Install the new handle assembly onto the enclosure 6 Reinstall the two1 4 20 screws and lock washers Make sure the handle housing is sealed against the enclosure flange as this prevents the entry of moisture 7 Reinstall the two screws that connect the handle link to the pivot assembly 9 Veri...

Reviews: