ENGLISH
Siemens AG
610.40068.01
9
A-grade sound intensity level
(EN 60034-9)
or speed range up to 3000 rpm
< 70 dB(A)
Thermischer Motorschutz
Temperature sensor KTY in the stator
(EN 60034-11)
winding and 3 serial connected PTC for
switch off
Shaft end
Cylindrical, without keyway
(DIN 748-3; IEC 60072-1)
Tolerance range k6
True running, coaxiality,
Tolerance N
axial run-out deviation
(DIN 42955; IEC 60072-1)
Vibration severity
Grade N
(EN 60034-14)
Bearing
Rolling contact bearing withou
permanent lubrication
(lifetime lubrication)
fixed bearing on non-drive end
Service live of bearing
20000 h (guideline)
Winding insulation
Temperature class H
(EN 60034-1)
Ambient temperatures
-15 °C to +40 °C (5 °F to 104 °F)
Otherwise the rated data are reduced
to 50°C: conversion factor 0,92
to 60°C: conversion factor 0,82
Installation altitude
up to 1000 m a.s.l.
(EN 60034-1)
2000 m: conversion factor 0,94
2500 m: conversion factor 0,9
Magnetic material
Rare-earth material
Encoder system
fitted encoder
- speed recording
- recording the rotor position
- indirect positional recording
Options/expansions
Type of protection
IP 65 included radial shaft seal
(EN 60034-5)
Fitted/mounted elements
- planetary gearing
Encoder systems
- incremental encoder sin/cos 1 Vpp
- absolute value encoder EnDat
True running, coaxiality,
Tolerance R
axial run-out deviation
(DIN 42955; IEC 60072-1)
Shaft end
Cylindrical, with keyway and feather key
(DIN 748-3; IEC 60072-1)
Tolerance range k6
(balancing with half feather key))
You will find more technical details, e.g. motor dimensions, in the catalog DA 65.3.