Description, technical data
2.9 Cooling
A5E01083943A AB
Siemens AG Operating Instructions 2.02 1FW4
35
NOTICE
Preventing condensation water
When the motor lies idle for long periods, shutdown the cooling circuit. Switch on the anti-
condensation heating if available.
The motors are designed in accordance with EN 60034-1 for operation up to a coolant
temperature of 25°C, assuming compliance with all motor data. If you operate a 1FW4 motor
with a higher coolant supply temperature and/or an ambient temperature > +40°C, you must
reduce the torque. Note the derating factors shown in the table below.
Table 2-7
Derating factors depending on the coolant supply temperature and the ambient
temperature
Coolant supply temperature to
25°C
30°C
35°C
40°C
45°C
Ambient temperature up to
40°C
45°C
50°C
55°C
60°C
Derating factor k
T
1.0
0.97
0.95
0.92
0.89
Cooling volumetric flow and water pressure
Table 2-8
Cooling volumetric flow and maximum permissible water pressure per shaft height
Shaft height
Cooling volumetric flow Maximum permissible
water pressure
1)
Thread sizes for water
connections
40
30 l/min
5 bar
G¾
45
50 l/min
5 bar
G1
503, 505
65 l/min
5 bar
G1½
507, 508
80 l/min
5 bar
G1½
1) Pressure drop: max. approx. 0.1 MPa (1 bar) - The pressure drop stops on its own.
Water quality
The cooling water must meet the following prerequisites:
●
Chemically neutral reaction
●
Water cleaned by solids
●
Max. particle size of particles carried: ≦ 0.1 mm
●
No salt water
Table 2-9
Chemical requirements of the water quality
Contents and chemical composition
Value
pH value
6.0 to 8.0 pH
Total hardness
< 170 ppm
Chloride
< 40 ppm
Sulphate
< 50 ppm
Summary of Contents for 1FW4
Page 1: ...Three phase synchronous motor HT direct Type 1FW4 Operating Instructions 01 2009 ht direct ...
Page 2: ...14 01 2009 16 26 ...
Page 24: ......
Page 40: ......
Page 60: ......
Page 88: ......
Page 92: ......
Page 102: ......
Page 108: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......