Transport, assembly, and connection
3.2 Assembly
A5E00215731A AD
Siemens AG Operating Instructions 2.02 1PL618
25
Please refer to the table below for the potential pressure drop inside the motor for motors
with a pipe connection:
Table 3-2
Pressure drop in motors with pipe connection
1PL6 18.
Volumetric flow (V)
Pressure drop (Δp)
0.27 m
3
/s
650 Pa
NOTICE
Please consider the additional pressure drop that arises in the system when connecting the
pipes.
Also ensure that:
●
you comply with the conditions of the IP degree of protection.
Higher IP requirements may necessitate the installation of suitable filters and special
positioning of the intake and outlet openings.
●
units and wires are mounted without distortion.
●
the shipping covers of the ventilation openings are removed.
Balancing quality
The rotors are balanced dynamically. In the case of shaft ends with feather keys, the method
used to balance the rotors can be identified from the following coding to be found on the end
face at the drive end of the shaft end:
●
Code "H" means balancing with half a feather key (standard version); this means that in
order to maintain the balancing quality it may be necessary to cut back the part of the
feather key protruding from the drive element and the shaft profile if the motor has a short
output element.
●
"F" means balancing with a whole featherkey (optional version).
Make sure that the balancing method of the output element is correct!
CAUTION
A suitable tool must always be used for fitting and pulling off output elements.
The feather keys are only locked against falling out during shipping.
Noise emission
Motors of the 1PL618. series have a measuring surface sound pressure level Lp(A) of
approx. 73 dB(A) + 3 dB (tolerance) in a speed range from 0 through 2000 rpm.