Function Blocks
UM353-1B
April
2012
3-56
Operator Display for Discrete indication & control
I 0
O
utput
0
INPUT 3
(H)
.........................
loop tag.block tag.output (null)
INPUT 2
(H)
.........................
loop tag.block tag.output (null)
INPUT 1
(H)
..........................
loop tag.block tag.output (null)
INPUT 0
(H)
.........................
loop tag.block tag.output (null)
INPUT 4
(H)
.........................
loop tag.block tag.output (null)
O0
I
nput
0 TAG
(S)
................................. 6 ASCII Char
(
I0 TAG)
I
nput
0
0
I
T A G
I N P U T
I
I
I
I
N
N
N
N
P
P
P
P
U
U
U
U
T
T
T
T
0
1
2
4
3
O
perator
D
isplay
for
D
iscrete indication
&
control
WD
W
atch
D
og
L
O P
#
LOOP #
(S)
................................................ 01 to 25
(null)
O D
W
I E
V
VIEW
O
perator
D
isplay
(H)
...................... NO/YES YES
O
ODD_
I 1
I
nput
1
I 2
I
nput
2
I 3
I
nput
3
I 4
I
nput
4
I 5
I
nput
5
I 6
I
nput
6
I 7
I
nput
7
I 8
I
nput
8
I 9
I
nput
9
I A
I
nput
A
I B
I
nput
B
I C
I
nput
C
I D
I
nput
D
I E
I
nput
E
I F
I
nput
F
O
utput
1
O1
O
utput
2
O2
O
utput
3
O3
O
utput
4
O4
O
utput
5
O5
O
utput
6
O6
O
utput
7
O7
O
utput
8
O8
O
utput
9
O9
O
utput
A
OA
O
utput
B
OB
O
utput
C
OC
O
utput
D
OD
O
utput
E
OE
O
utput
F
OF
I
nput
1 TAG
(S)
................................. 6 ASCII Char
(
I1 TAG)
1
I
T A G
I
nput
2 TAG
(
S)
................................. 6 ASCII Char
(
I2 TAG)
2
I
T A G
I
nput
3 TAG
(S)
................................. 6 ASCII Char
(
I3 TAG)
3
I
T A G
I
nput
4 TAG
(S)
................................. 6 ASCII Char
(
I4 TAG)
4
I
T A G
I
nput
5 TAG
(S)
................................. 6 ASCII Char
(
I5` TAG)
5
I
T A G
I
nput
6 TAG
(S)
................................. 6 ASCII Char
(
I6 TAG)
6
I
T A G
I
nput
7 TAG
(S)
................................. 6 ASCII Char
(
I7 TAG)
7
I
T A G
I
nput
8 TAG
(S)
................................. 6 ASCII Char
(
I8 TAG)
8
I
T A G
I
nput
9 TAG
(S)
................................. 6 ASCII Char
(
I9 TAG)
9
I
T A G
I
nput
A TAG
(S)
................................. 6 ASCII Char
(
IA TAG)
A
I
T A G
I
nput
B TAG
(S)
................................. 6 ASCII Char
(
IB TAG)
B
I
T A G
I
nput
C TAG
(S)
................................. 6 ASCII Char
(
IC TAG)
C
I
T A G
I
nput
D TAG
(S)
................................. 6 ASCII Char
(
ID TAG)
D
I
T A G
I
nput
E TAG
(S)
................................. 6 ASCII Char
(
IE TAG)
E
I
T A G
I
nput
F TAG
(S)
................................. 6 ASCII Char
(
IFTAG)
F
I
T A G
INPUT 8
(H)
.........................
loop tag.block tag.output (null)
INPUT 7
(H)
.........................
loop tag.block tag.output (null)
INPUT 6
(H)
..........................
loop tag.block tag.output (null)
INPUT 5
(H)
.........................
loop tag.block tag.output (null)
INPUT 9
(H)
.........................
loop tag.block tag.output (null)
I N P U T
I
I
I
I
N
N
N
N
P
P
P
P
U
U
U
U
T
T
T
T
5
6
7
9
8
INPUT A
(H)
.........................
loop tag.block tag.output (null)
I N P U T
A
INPUT E
(H)
.........................
loop tag.block tag.output (null)
INPUT D
(H)
.........................
loop tag.block tag.output (null)
INPUT C
(H)
..........................
loop tag.block tag.output (null)
INPUT B
(H)
.........................
loop tag.block tag.output (null)
INPUT F
(H)
.........................
loop tag.block tag.output (null)
I N P U T
I
I
I
I
N
N
N
N
P
P
P
P
U
U
U
U
T
T
T
T
B
C
D
F
E
.
Rev. 3
3.2.56 ODD - Operator Display for Discrete Indication & Control
ODD function blocks are one of five operator displays that
can be used on a one per loop basis to configure the local
operator display functions as well as network parameters.
See the i|ware PC faceplate example on the next page.
The ODD function block displays up to 16 discrete
variables. Each input has a corresponding block output
that is equal to the input when the variable mode is in
Auto. Each input variable can be assigned a mode. The
value of the output can be changed while in Man by using
the pulser and pressing the ACK button. When a variable
is switched to Manual it will always equal the input value
until changed.
The LOOP # parameter is used to index reads and writes
to Modbus parameters. See Section 5 for more
information on network parameters.
The VIEW OD parameter, when set to YES enables the
operator display to be viewed and accessed locally. In
cases where it is desired to view display or operation
parameters only from a network workstation, the
parameter should be set to NO.
During a cold or warm start, each input variable will
power up in the auto mode. During a hot start, the mode
and manual value will equal the value prior to power
down.
Each discrete input variable can be displayed on the local
faceplate using the D button. When first stepping into a
loop using the Loop button, the loop tag will be displayed
(e.g. DigDisp1). Pressing the D button will scroll through
the discrete points displaying the point tag (e.g. SV-103)
in the alphanumeric and the value of the input on the left 3
positions of the digital display (e.g. On) and the output in
the right most 3 positions (e.g. OFF).
The A/M button will display the point mode and enable
switching the point between auto & manual using the A/M
button. The manual value can be changed by turning the
pulser and pressing the ACK button. If the ACK button is
not pressed within 4-5 seconds, the display will return to
the actual output value.
Summary of Contents for 353
Page 12: ...Contents UM353 1B x April 2012 ...
Page 22: ...Introduction UM353 1B April 2012 1 10 ...
Page 30: ...Configuration Overview UM353 1B April 2012 2 8 ...
Page 122: ...Function Blocks UM353 1B April 2012 3 92 ...
Page 168: ...Data Mapping UM353 1B April 2012 6 28 ...
Page 204: ...Controller and System Test UM353 1B April 2012 9 8 ...
Page 222: ...Calibration UM353 1B April 2012 11 4 ...
Page 226: ...Circuit Description UM353 1B April 2012 12 4 ...
Page 238: ...Model Designation and Specifications UM353 1B April 2012 13 12 EC Declaration of Conformity ...
Page 240: ...Model Designation and Specifications UM353 1B April 2012 13 14 ...
Page 244: ...Abbreviations And Acronyms UM353 1B 14 4 April 2012 ...