Description of the individual safety relays
3.8 3TK28 safety relays with contactor relay enabling circuits
3TK28 safety relays
Manual, 07/2016, NEB926157502000/RS-AB/003
153
Technical data 3TK2852
3TK2852-.A...
3TK2852-.B...
EMC emitted interference
IEC 60947-5-1, IEC 60000-4-3,
IEC 60000-4-5, IEC 60000-4-6
Item designation
•
according to DIN 40719 extendable after IEC 204-2
according to IEC 750
KT
•
according to DIN EN 61346-2
F
Number of sensor inputs 1-channel or 2-channel
1
Design of the cascading
none
Type of the safety-related wiring of the inputs
single-channel and two-channel
Product feature transverse contact-secure
Yes
Safety Integrity Level (SIL) according to IEC 61508
SIL2
SIL claim limit (for a subsystem) according to EN 62061
2
Safety integrity level (SIL) for delayed release circuit
according to IEC 61508
—
Performance Level (PL)
•
according to ISO 13849-1
d
•
for delayed release circuit according to ISO 13849-1
—
Category
•
according to EN 954-1
3
•
according to ISO 13849-1
3
Safety device type according to IEC 61508-2
Type B
Probability of dangerous failure per hour (PFHD) with
high demand rate according to EN 62061
1/h 0.000000011
T1 value for proof test interval or service life according
to IEC 61508
a 20
Number of outputs as contact-affected switching element
as NO contact safety-related
•
as NC contact for reporting function instantaneous
switching
1
•
as NO contact safety-related instantaneous switching
6
•
as NO contact safety-related delayed switching
0
Stop category according to DIN EN 60204-1
0
Design of the input
•
cascading-input/functional switching
No
•
feedback input
Yes
•
start input
Yes