9 – 60
Displaying measured-values
Example 1: Displaying the currents
Example 2: Displaying the frequency
M A I N
M E N U
M E T E R I N G
C U R R E N T
I
L
1
M e t e r i n g
I
a
v
g
=
7 5 2
A
I
L
1
=
7 6 5
A
I
L
1
m i
n
=
7 0 6
A
D i a g n o s t i c
U
a
v
g
=
4 0 1
V
2 8 - J A N -
0 1
V i e w
P a r a m e t e r
P
= +
2 7 7
I
L
2
=
7 5 8
A
1 6 :
2 9 :
3 2 .
0 1
C h a n g e
P a r a m e t e r
S
=
3 0 2
k V A
I d e n t i f i c a t i o n
Q
= +
1 2 0 k V A R
I
L
3
=
7 5 0
A
I
L
1
m a
x
=
7 8 8
A
R e s e t s
p f
a
v
g
=
0 .
9 1 8
l a g
0 4 - J A N -
0 1
D i s p l a y S e t u p
W
= + 2 1 2 0 7 M W h r
I
N
=
0
A
0 8 :
5 9 :
3 8 .
2 1
f r e q
=
5 0 .
0 2
H z
M E T E R I N G
C U R R E N T
U
a
v
g
=
4 0 1
V
I
g
=
5
A
P
= +
2 7 7
S
=
3 0 2
k V A
I
a
v
g
=
7 5 2
A
Q
= +
1 2 0 k V A R
p f
a
v
g
=
0 .
9 1 8
l a g
I
a
v
g
l
t
=
7 5 2
A
W
= + 2 1 2 0 7 M W h r
f r e q
=
5 0 .
0 2
H z
U n b a l . =
1 0
%
T e m p
=
2 2 5 .
0
F
(en
ter)
(esc)
kW
(down 8x)
(up 8x)
(down 7x)
(up 7x)
kW
(en
ter)
(esc)
(en
ter)
(esc)
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
M A I N
M E N U
M E T E R I N G
F R E Q U E N C Y
F R E Q
M e t e r i n g
I
a
v
g
=
7 5 2
A
f
r
e
q
=
5 0 .
0 2
H z
f
r
e
q
m i
n
=
5 0 .
0 2
H z
D i a g n o s t i c
U
a
v
g
=
4 0 1
V
2 8 - J A N - 0 1
V i e w
P a r a m e t e r
P
= +
2 7 7
I
T
H D
=
1 0
%
1 6 : 2 9 : 3 2 .
0 1
C h a n g e
P a r a m e t e r
S
=
3 0 2
k V A
I d e n t i f i c a t i o n
Q
= +
1 2 0 k V A R
U
T
H D
=
1 0
%
f
r
e
q
m a
x
=
5 0 .
0 2
H z
R e s e t s
p f
a
v
g
=
0 .
9 1 8
l a g
0 4 - J A N - 0 1
D i s p l a y S e t u p
W
= + 2 1 2 0 7 M W h r
F o r m F =
4 .
0
0 8 : 5 9 : 3 8 .
2 1
f r e q
=
5 0 .
0 2
H z
C r e s t F =
4 .
0
M E T E R I N G
F R E Q U E N C Y
U
a
v
g
=
4 0 1
V
H a r m o n i c s
P
= +
2 7 7
S
=
3 0 2
k V A
Q
= +
1 2 0 k V A R
p f
a
v
g
=
0 .
9 1 8
l a g
W
= + 2 1 2 0 7 M W h r
f r e q
=
5 0 .
0 2
H z
T e m p
=
2 2 5 .
0
F
(en
ter)
(esc)
k W
(up 8x)
(down5x)
(up 5x)
(down 8x)
(en
ter)
(esc)
(en
ter)
(esc)
kW
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
PAR
A
TRIG
AB
Summary of Contents for 3ZX1812-0WL00-0AN2
Page 91: ...9 15 S Auslösung I Auslösung S tripping I tripping ...
Page 92: ...9 16 Erdschlussauslösung Ground fault tripping ...
Page 121: ...English part continued on Page 9 60 9 45 ...
Page 135: ...English part continued on Page 9 60 9 59 ...
Page 149: ...9 73 ...
Page 307: ...19 10 Einbau Baugröße Frame size Länge L mm Length L mm I 48 II 118 III 232 1 Fitting ...
Page 317: ...20 2 Vertikal Vertical Einschubtechnik Draw out version Horizontal Horizontal ...
Page 362: ...5HOHDVH ...
Page 363: ...5HOHDVH 5 H OH D V H ...