12.3.3 LAN Interface
The UPS Solution’s LAN interface can be accessed via the Alpha FXM UPS unit’s
embedded SNMP (LAN) card using the RJ45 socket on the unit itself. If the solution’s
Ethernet Cable is fitted and a TCP/IP based network connection is available within the
traffic controller, the LAN interface can be accessed remotely from any other active
network device.
To connect to the LAN interface, type the Alpha FXM UPS unit’s IP address into a web
browser. Individual unit’s IP addresses can be configured to match networking required.
The default IP address and password for all UPS units are shown in Table 12-5.
Connection Parameters
Default Settings
IP Address
192.168.0.90
Password
1111
Table 12-5: LAN Interface Connection Information
NOTE:
The connection password applies to all UPS communication interfaces
described in section 12.3.
Connecting to the LAN interface presents the user with a simple GUI that gives access to
the greatest number of system settings and configurations under the following top level
page menu.
•
UPS
Specification
•
UPS
Monitoring
•
UPS
Maintenance
•
Event
Manager
•
Upgrade
Files
•
Configure Site Information
•
Communications
•
Keep
Alive
The UPS Solution’s operating mode and fault / alarm flags are always displayed at the
top of each page for easy system monitoring.