Technical specifications
7.2 Technical specifications
Carrier controller
42
Operating Instructions, 09/2013, A5E03474162-02
7.2
Technical specifications
Mechanical system
Parameter
Value
Length, width, height (overall)
481.5 × 300 × 128 mm
Weight
10.0 kg
Data interfaces
Parameter
Value
Programming interface
PROFINET
Signal on RAIL A and RAIL B
48 V AC, modulated
See "EMS400S PSB Modules" operating
instructions.
Power supply
Parameter
Value
Current type
Three-phase AC
Line frequency
50/60 Hz
Voltage
400 V AC
Current consumption on 400 V AC, typical
0.37 A
Current consumption on 400 V AC, maximum
0.64 A
Inrush current
≤ 16 A; 0.5 mains periods
Power losses, typical
40 W
Power losses, maximum
48 W
Geared motor
370 W
The system has to protect the energy supply of the carrier controller (overcurrent protection)
with a 3-phase circuit-breaker with a rated current of max. 63 A. Otherwise, a 3-phase
protection device (miniature circuit breaker) with a rated current of 63 A and tripping
characteristic C can be used.
Fan monitoring
The speed signal of the fan is a square wave signal. The signal can be evaluated, for
example, by the high speed counter of the digital input DI 0 of the S7-1212 CPU. For more
information, refer to:
"S7-1200 Automation System" system manual
http://support.automation.siemens.com/WW/view/de/36932465/0/en
Parameter
Value
Speed signal, normal
Time period 8.6 ms at 3500 min
–1