X20: Enabling buttons
Connector designa‐
tion:
X20
Connector type:
8-pin Phoenix terminal
Table 4-5
Assignment of the interface enabling buttons X20
Pin
Signal name
Signal type
Meaning
1
ZUST1P
I
Enabling button 1 P
2
ZUST1M
O
Enabling button 1 M
3
ZUST2P
I
Enabling button 2 P
4
ZUST2M
O
Enabling button 2 M
5
N.C.
-
Not connected
6
N.C.
-
Not connected
7
N.C.
-
Not connected
8
N.C.
-
Not connected
X21: Emergency Stop and key-operated switch
Connector designa‐
tion:
X21
Connector type:
10-pin Phoenix terminal
Table 4-6
Assignment of the interface Emergency Stop and Module Supply Voltage
Pin
Signal name
Signal type
Meaning
1
STOP23
B
Emergency Stop circuit
2
STOP24
Emergency Stop circuit
3
STOP13
Emergency Stop circuit
4
STOP14
Emergency Stop circuit
5
M
P
Ground
6
N.C.
-
-
7
IN_E9
P
Connected P24 (jumpered to Pin8 during opera‐
tion)
8
P24_FILT
Filtered 24 V module power supply
9
IN_E9_EXT
O
Feedback signal via connected P24
10
IN_E12_EXT
"High": Terminating connector plugged in
Note
Pins 7 and 8 must be jumpered in order to supply a handheld terminal with power.
Connecting
4.5 PN Basic connection module
Handheld Terminal HT 10
Equipment Manual, 09/2020, A5E47430965B AA