SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03
53
Appendix
A
A.1
Code configurations
Note
Changing the configuration
Changes to the configuration take effect immediately and are stored.
Note
Rate of data transmission depends on set keyboard
Note that the data transmission rate is slower with a set universal keyboard (Universal
Keyboard Mapping) than with selection of a specific keyboard language (e.g. US keyboard).
SIMATIC MV320
Codes for configuration of the device
A current list of the codes for configuration of the SIMATIC MV320 reader is available at the
following link:
SIMATIC MV320 Configuration guide
https://support.industry.siemens.com/cs/ww/en/ps/15160/man
Motion detection with the reader with and without stand detection
If the reader is placed on a stand, the reader with stand detection automatically switches to
the motion detection mode.
●
When the code for "Disable Motion Detection with Stand Detection" is scanned in, the
reader switches to the motion detection mode. Detection depends on whether or not the
reader is on a stand.
●
To disable motion detection, you need to scan in the code for "Disable Motion Detection
with Stand Detection" and "Motion Detection Scanning Off".
●
To enable motion detection on readers with stand detection after disabling motion
detection:
You need to scan in the code for "Enable Motion Detection with Stand Detection"
●
To enable motion detection on readers without stand detection:
You need to scan in the required code for "Motion Detection On".