Settings in WBM
In WBM, you can set the monitoring of the power supply (SCALANCE X204RNA only) and the
device-related link monitoring. The settings are made in three separate dialog boxes:
Figure 9-20
SCALANCE X204RNA Fault Mask Power Monitoring
Enable Power Monitoring (SCALANCE X204RNA only)
Here, you specify which of the two power supplies of the SCALANCE X204RNA (line 1 and line
2) is monitored. A fault is then indicated by the message system when there is no power on one
of the monitored lines (line 1 or line 2) or when the voltage is too low (less than 14 V).
Note
This dialog box is not displayed with the SCALANCE X204RNA EEC because it does not have a
redundant power supply.
Functional description and configuration using Web Based Management
9.8 The "X200" menu
SCALANCE X-200RNA
112
Operating Instructions, 04/2022, C79000-G8976-C342-07