6.6
Wall mounting
Wall mounting of a SCALANCE X204RNA
Preparation for wall mounting
Wall mounting
To mount the device on a wall, you require the following:
• 2 wall plugs, 6 mm in diameter and 30 mm long
• 2 screws 3.5 mm in diameter and 40 mm long
To install a SCALANCE X204RNA on a standard rail, follow the steps below:
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawings".
2. Connect the electrical cable connecting cables.
3. Fit the connectors for the signaling contact.
4. Insert the terminal blocks into the sockets on the SCALANCE X204RNA.
5. Screw the device to the wall.
Note
The wall mounting must be capable of supporting at least four times the weight of the
SCALANCE X204RNA (see "Technical specifications (Page 149)").
Wall mounting of a SCALANCE X204RNA EEC
To mount the device on a wall, you require the following:
• 2 wall plugs, 6 mm in diameter and 30 mm long
• 2 screws 3.5 mm in diameter and 40 mm long
Installation and disassembly
6.6 Wall mounting
SCALANCE X-200RNA
66
Operating Instructions, 04/2022, C79000-G8976-C342-07