How to download data using HTTP
1. In the relevant text box, enter a name and directory path for the file from which you want to
take the data.
2. Start the download of the relevant file by clicking one of the buttons "Load Configuration and
Restart", "Load Firmware and Restart" or "Load FPGA File and Restart", "Load Private Key" or
"Load Certificate and Restart". Following the download, there is an automatic restart except
with "Load Private Key" and the device starts up with the new data. Please note the following:
Note
If a firmware version is loaded that is older than the current version, it is possible that the
current parameter record cannot be adopted. In this case the current IP address is deleted and
access using WBM, CLI or SNMP is no longer possible. This means that after downloading the
firmware and restarting the device, the IP address needs to be assigned again with the
SINEC PNI and the required parameters set again.
Note
If newer firmware and a newer FPGA version required on the device, it is advisable to
download the FPGA and then the firmware following the restart.
How to save data using HTTP
1. Start the save function by clicking either the "Save Configuration" or "Save Private MIB"
button.
2. You will be prompted to select a storage location and a name for the file or to accept the
proposed file name.
Reusing configuration data
Saving and reading in configuration data reduces the effort if several devices of the SCALANCE
X-200RNA product line have the same configuration and when IP addresses are obtained using
DHCP.
Save the configuration data on your computer after you have configured a SCALANCE X-200RNA.
Download this file to all other devices of the SCALANCE X-200RNA product line you want to
configure.
If individual settings are necessary for specific devices, these must be made online.
The stored configuration data is coded and, as a result, these files cannot be edited with a text
editor.
Functional description and configuration using Web Based Management
9.7 The "System" menu
SCALANCE X-200RNA
98
Operating Instructions, 04/2022, C79000-G8976-C342-07