NOTICE
The maximum operating temperature depends on the transceiver you are using
The following temperature limits apply for the individual transceivers:
SFP992-1: 60 °C
SFP992-1LD: 55 °C
SFP992-1LH: 50 °C
SFP992-1LH+: 50 °C
SFP992-1ELH: 45 ℃
If a SCALANCE W786 -2 SFP is operated at a temperature higher than the specified temperature,
the device and transceiver may be damaged. For this reason, do not use the SCALANCE in
ambient temperatures above the specified temperature limits.
NOTICE
Use only approved SFP transceivers
If you use SFPs not approved by Siemens AG, Siemens cannot accept any responsibility for the
correct functioning of the device according to the specification.
If components are used that have not been Siemens approved, Siemens cannot vouch for their
compatibility or for risk-free use of these components.
You will find detailed information on installing and connecting transceivers in the "Operating
Instructions SFP/SFP+ Transceiver". This document is included on the data medium that came
with the SCALANCE W786.
NOTICE
Insert and remove transceivers only when the power is off
SFP/SFP+ transceivers may only be inserted in or removed from an SFP slot when the power
supply to the device has been turned off.
Connecting up
6.7 SFP/SFP+ transceivers
SCALANCE W786-x
Operating Instructions, 12/2021, A5E03678337-14
63
Summary of Contents for 6GK5786-1FC00-0AA0
Page 8: ...Introduction SCALANCE W786 x 8 Operating Instructions 12 2021 A5E03678337 14 ...
Page 10: ...Safety notices SCALANCE W786 x 10 Operating Instructions 12 2021 A5E03678337 14 ...
Page 66: ...Maintenance and cleaning SCALANCE W786 x 66 Operating Instructions 12 2021 A5E03678337 14 ...
Page 82: ...Dimension drawings SCALANCE W786 x 82 Operating Instructions 12 2021 A5E03678337 14 ...
Page 84: ...Certification SCALANCE W786 x 84 Operating Instructions 12 2021 A5E03678337 14 ...