09.02
Connection
Siemens AG 6SE7087-6AK85-1AA0
3-5
Rectifier/Regenerating Unit Operating instructions
The units are designed for permanent connection to the system in keeping with DIN VDE 0160 Section 6.5.2.1.
Protective conductor connection: Min. cross-sectional area 10 mm
2
(see Table 3.2).
The conductor cross-sectional areas listed in Table 3.2 are maximum connectable cross-sections. The data is
given for multicore cable. The cross-sectional areas actually wired and the associated connection elements
must be selected according to the currently valid standards - e.g. DIN VDE 100 Part 523, DIN VDE 0276 Part
1000, UL, CSA, ....
Unit Order No.
Mains
DC link
Protective conductor
Rated
input
Conductor
U1/L1, V1/L2,W1/L3
1U2/1T1, 1V2/1T2,
1W2/1T3
Conductor
C/L+, D/L-
Conductor
PE
voltage
current
max.
max.
max.
max.
6SE70
(V)
(A)
mm
2 1)
AWG
2)
mm
2 1)
AWG
2)
mm
2 1)
AWG
2)
22-1EC85-1AA0 380 to 480
18
50
3)
1/0 50
3)
1/0 10
10
24-1EC85-1AA0 380 to 480
36
50
3)
1/0 50
3)
1/0 16
6
28-6EC85-1AA0 380 to 480
74
50
3)
1/0 50
3)
1/0 25
4
31-7EE85-1AA0 380 to 480
149
2x120
2x4/0
2x150
2x300
70
2/0
32-2EE85-1AA0 380 to 480
192
2x120
2x4/0
2x150
2x300
95
3/0
33-1EE85-1AA0 380 to 480
269
2x120
2x4/0
2x150
2x300
150
300
33-8EE85-1AA0 380 to 480
326
2x240
2x500
2x300
2x600
185
350
34-6EE85-1AA0 380 to 480
403
2x240
2x500
2x300
2x600
240
500
36-1EE85-1AA0 380 to 480
526
2x240
2x500
2x300
2x600
300
600
38-2EH85-1AA0 380 to 480
710
C 4x300
R 100x10
4x600 C
4x300
R 60x10
4x600 C
4x300
R 100x10
4x600
41-0EH85-1AA0 380 to 480
888
C 4x300
R 100x10
4x600 C
4x300
R 60x10
4x600 C
4x300
R 100x10
4x600
41-3EK85-1AA0 380 to 480
1156
C 4x300
R 100x10
4x600 C
6x300
R 100x10
6x600 C
4x300
R 100x10
4x600
41-3EK85-1AD0 380 to 480
1156
C 4x300
R 100x10
4x600 C
6x300
R 100x10
6x600 C
4x300
R 100x10
4x600
41-8EK85-1AA0 380 to 480
1542
C 4x300
R 100x10
4x600 C
6x300
R 100x10
6x600 C
4x300
R 100x10
4x600
41-8EK85-1AD0 380 to 480
1542
C 4x300
R 100x10
4x600 C
6x300
R 100x10
6x600 C
4x300
R 100x10
4x600
22-7FC85-1AA0 500 to 600
24
50
3)
1/0 50
3)
1/0 10
8
24-1FC85-1AA0 500 to 600
36
50
3)
1/0 50
3)
1/0 16
6
27-2FC85-1AA0 500 to 600
62
50
3)
1/0 50
3)
1/0 16
6
28-8FC85-1AA0 500 to 600
82
50
3)
1/0 50
3)
1/0 25
4
31-5FE85-1AA0 500 to 600
131
2x120
2x4/0
2x150
2x300
70
2/0
32-4FE85-1AA0 500 to 600
203
2x120
2x4/0
2x150
2x300
120
4/0
32-7FE85-1AA0 500 to 600
233
2x120
2x4/0
2x150
2x300
120
4/0
33-5FE85-1AA0 500 to 600
307
2x240
2x500
2x300
2x600
185
350
34-2FE85-1AA0 500 to 600
366
2x240
2x500
2x300
2x600
185
350
1) C=Cable, R=Rail
2) American Wire Gauge
3) Terminal connection area: Multicore10mm
2
to 50mm
2
AWG 8 to AWG 1/0
Stranded
3.5mm
2
to 35mm
2
AWG 12 to AWG 2