4
05.01
4.2 ”SIMODRIVE 611 universal HRS” control board
4-103
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
S
Resolvers
Table 4-13
Encoder signal input of motor encoder X411, X412 (resolver)
Pin
X411 (axis 1)
X412 (axis 2)
Function
1
–
Reserved, do not use
2
M
Ground
3
AP
Resolver, sinusoidal
4
AN
Resolver, sinusoidal, inverted
5
M
Inner shield ground
6
BP
Resolver, cosine
7
BN
Resolver, cosines, inverted
8
M
Inner shield ground
9
EXC_POS
Resolver excitation (pos.)
10
–
Reserved for test purposes, do not use
11
EXC_NEG
Resolver excitation (neg.)
12
–
Reserved for test purposes, do not use
13
THMOTP
KTY 84 (+) temperature sensor
14
–
Reserved, do not use
15
–
Reserved for test purposes, do not use
16
–
Reserved, do not use
17
–
Reserved, do not use
18
–
Reserved, do not use
19
–
Reserved, do not use
20
–
Reserved, do not use
21
–
Reserved, do not use
22
–
Reserved, do not use
23
–
Reserved, do not use
24
M
Inner shield ground
25
THMOTCOM
KTY 84 (–) temperature sensor
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunctions can occur.