4.3 ”HLA module” control board
4-107
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
4.3.2
Wiring
The SINUMERIK 840D and the HLA module are supplied from the
SIMODRIVE line supply infeed or from the SIMODRIVE monitoring module via
the equipment bus. There must be at least one NE module in the equipment
group when an HLA module is used. No provision has been made for any other
type of voltage supply and failure to use the supply provided could damage the
unit.
Note
It is not permissible to operate an HLA module on its own with a SIMODRIVE
monitoring module!
Power is supplied to downstream electrical axes via the DC link busbars (40
mm
2
) of the carrier module.
One position encoder for each axis can be evaluated on the HLA module.
S
X101:
Axis 1
S
X102:
Axis 2
The measuring system must always be plugged into the connector of the asso-
ciated axis.
Table 4-14
Connectors X101, X102; 15–pin sub–D plug connector (two–tier)
Pin
X101
1)
X102
1)
Function
1
PENC0
PENC2
Encoder power supply 5 V
$
5%, 300 mA
2
M
M
Encoder power supply ground
3
AP0
AP2
Incremental signal for track A
4
AN0
AN2
Inverse incremental signal for track A
5
ENDATDAT0
ENDATDAT2
EnDat or SSI interface data signal
6
BP0
BP2
Incremental signal for track B
7
BN0
BN2
Inverse incremental signal for track B
8
XENDATDAT0
XENDATDAT2
Inverse EnDat or
SSI interface data signal
9
PSENSE0
PSENSE2
Remote sense encoder power supply (P)
10
RP0
RP2
Zero pulse/reference mark signal A
11
MSENSE0
MSENSE2
Remote sense encoder power supply (M)
12
RN0
RN2
Inverse zero pulse/reference mark signal A
13
M
M
Ground (for internal shields)
14
ENDATCLK0
ENDATCLK2
EnDat or SSI interface clock signal
15
XBMICLK0
XBMICLK2
Inverse EnDat interface clock signal
Note: The SSI encoder requires an external 24 V power supply
1)
The permissible voltage range for the common mode component of the
individual encoder signals (AP. AN. BP, BP, RP, RP) is 1.5...3.5 V.
Line supply
connection
Measuring
systems
4 Control Units
02.07
02.12