4
05.01
4.3 ”HLA module” control board
4-108
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Connection for two pressure sensors per axis
S
X111:
Axis 1 (sensors 1A, 1B)
S
X112:
Axis 2 (sensors 2A, 2B)
Table 4-15
Connectors X111, X112; each 15–pin sub–D socket connector
Pin
X111
X112
Type
1)
Function
1
P24DS
P24DS
O
Ex24 V supply for the
pressure sensor
2
P24DS
P24DS
O
Ex24 V supply for the
pressure sensor
3
–
–
–
Not assigned
4
–
–
–
Not assigned
5
M24EXT
M24EXT
O
External 0 V supply for the
pressure sensor
6
–
–
–
Not assigned
7
–
–
–
Not assigned
8
–
–
–
Not assigned
9
M24EXT
M24EXT
O
External 0 V supply for the
pressure sensor
10
M24EXT
M24EXT
O
Extra pin for jumper between pins 10–11 with
3–wire connection
11
PIST1BN
PIST2BN
I
Analog actual value signal, reference ground
12
PIST1BP
PIST2BP
I
Analog actual value signal, max. range 0...10 V
13
M24EXT
M24EXT
O
Extra pin for jumper between pins 13–14 with
3–wire connection
14
PIST1AN
PIST2AN
I
Analog actual value signal, reference ground
15
PIST1AP
PIST2AP
I
Analog actual value signal, max. range 0...10 V
1)
I = Input, O = Output
The inputs are differential with 40 k
Ω
input resistance.
The input voltage range is 0...+10 V.
The supply output has an electronic short–circuit protection function.
The supply output is dimensioned for a total current (4 sensors) of 200 mA.
Supply for pressure sensors with 26.5 V
"
2% according to the external infeed
at X431.
Notice
The external 26.5 V supply voltage cannot be replaced by a 24 V supply
voltage.
Pressure sensor
system
4 Control Units