5
05.01
5.3 Technical data
5-125
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 5-1
Power modules in the 1–axis version
6SN112
j
–1AA0
j
–
3 internal cooling
4 external cooling
1)
0HA
j
0AA
j
0BA
j
0CA
j
0DA
j
0LA
j
0EA
j
0FA
j
0JA
j
0KA
j
Mounting frame external
cooling 6SN1162–0BA04–
0AA
j
0FA
j
0BA
j
0CA
j
0EA
j
Type of cooling
Non–
ventilated
Fan
For operation of induction motors
Nominal current I
n
A
eff
3
5
8
24
30
45
60
85
120
200
Current for S6–40% I
S6–40%
A
eff
3
5
10
32
40
60
80
110
150
250
Peak current I
max
A
eff
3
8
16
32
51
76
102
127
193
257
Inverter pulse frequency f
0
kHz
3.2
Derating factor X
L
%
50
55
50
55
Power loss, total P
Vtot
W
30
40
74
260
320
460
685
850
1290
2170
Power loss, internal P
Vint
W
12
16
29
89
32
19
30
100
190
325
Power loss, external P
Vext
W
18
24
45
171
288
441
655
750
1100
1845
For operation of synchronous motors
Nominal current I
n
A
eff
3
5
9
18
28
42
56
70
100
140
Peak current I
max
A
eff
6
10
18
36
56
64
112
140
100
210
Inverter pulse frequency f
0
kHz
4
Derating factor X
L
%
55
50
55
Power loss, total P
Vtot
W
35
50
90
190
300
460
645
730
1300
1910
Power loss, internal P
Vint
W
14
19
35
65
30
25
25
90
170
250
Power loss, external P
Vext
W
21
31
55
125
270
435
620
640
1130
1660
General technical data for the regulated infeed
Input voltage
V DC
Regulated: 600 V or 625 V DC, unregulated: U
DC link
=U
Supply
1.35
Maximum output voltage
V
eff
U
a_max
= U
DC link
/1.4
Minimum motor current I
min
5)
A
0.6
1.1
1.8
3.6
5.7
8.5
11
14
21
28
Transistor limit current
A
8
15
25
50
80
108
160
200
300
400
Efficiency
0.98
Module width
mm
50
100
150
300
2)
Weight, approx.
kg
6.5
9.5
13
26
28
Maximum air flow of fan
(volumetric flow, unobstructed
flow per fan)
m
3
/hr
–
–
19
22
56
2x56
2x56
3)
2x51
2)
–
–
Motor connection
Connectors
Terminals
1) For a module width of 300 mm with external cooling, mounting frames are required that must be separately ordered.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be separately ordered! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown
in this Configuration Manual.
2) For 6SN1123–1AA0
j
–0JA
j
/0KA
j
and 6SN1124–1AA0
j
–0FA
j
/–0JA
j
/–0KA
j
, the built–on fan
6SN1162–0BA02–0AA2 is required.
3) Is applicable for internal cooling. For external cooling with mounted fan 2) 400 m3/h
4) True for induction motors and applies to the no–load current.
5 Power Modules
10.04