5
05.01
5.3 Technical data
5-126
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 5-2
Power modules in the 2–axis version
6SN112
j
–1AB00–
3 internal cooling
4 external cooling
0HA
j
0AA
j
0BA
j
0CA
j
Mounting frame external
cooling 6SN1162–0BA04–
0AA
j
0GA
j
Type of cooling
Fan
For operation of induction motors
1)
Nominal current I
n
A
eff
3
5
8
24
Current for S6–40% I
S6–40%
A
eff
3
5
10
32
Peak current I
max
A
eff
3
8
16
32
Inverter pulse frequency f
0
kHz
3.2
Derating factor X
L
%
55
Power loss, total P
Vtot
W
76
118
226
538
Power loss, internal P
Vint
W
28
42
74
184
Power loss, external P
Vext
W
48
76
152
354
For operation of synchronous motors
Nominal current I
n
A
eff
3
5
9
18
Peak current I
max
A
eff
6
10
18
36
Inverter pulse frequency f
0
kHz
4
Derating factor X
L
%
55
Power loss, total P
Vtot
W
70
100
180
380
Power loss, internal P
Vint
W
27
38
69
130
Power loss, external P
Vext
W
43
62
111
250
General technical data for the regulated infeed
Input voltage
V DC
regulated: 600 V or 625 V DC, unregulated: U
DC link
=U
Supply
1.35
Maximum output voltage
V
eff
U
a_max
= U
DC link
/1.4
Minimum motor current I
min
2)
A
0.6
1.1
1.8
3.6
Transistor limit current
A
8
15
25
50
Efficiency
0.98
Module width
mm
50
100
Weight, approx.
kg
7
13.5
Maximum air flow of fan
(volumetric flow)
m
3
/hr
–
–
19
56
Motor connection
Connectors
1) For IM operation, corresponding to the selected 4/8 kHz inverter pulse frequency, an appropriate derating must be
observed.
2) True for induction motors and applies to the no–load current.
5 Power Modules
10.04
05.08