5.6 Interfaces and terminals
5-137
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
5.6.2
Connectable cable cross–sections
The cable cross–sections that can be connected are listed in Table 5-7:
Table 5-7
Cable cross–sections that can be connected at the power module (motor connection)
MLFB
Connection cross–section [mm
2
]
1)
2)
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
[Nm]
6SN112
j
–1AA00–0KA
V
400 A
X
M6
25...30
6SN112
j
–1AA00–0JA
V
300 A
X
M6
15...20
6SN112
j
–1AA01–0FA
V
200 A
X
M6
15...20
6SN1123–1AA02–0FA
V
200 A
X
M6
15...20
6SN112
V
–1AA00–0EA
V
160 A
X
M6
6...8
6SN112
V
–1AA00–0LA
V
108 A
X
M6
6...8
6SN1123–1AA00–0DA
V
80 A
X
M5
1,5...1,8
6SN112
V
–1AA00–0CA
V
50 A
X
X
X
X
M5
0,7...0,8
6SN112
V
–1AA00–0BA
V
25 A
X
X
X
X
M5
0,7...0,8
6SN112
V
–1AA00–0AA
V
15 A
X
X
X
X
M5
0,7...0,8
6SN112
V
–1AA00–0HA
V
8 A
X
X
X
X
M5
0,7...0,8
6SN112
V
–1AB00–0CA
V
2x50 A
X
X
X
X
M5
0,7...0,8
6SN1123–1AB00–0BA
V
2x25 A
X
X
X
X
M5
0,7...0,8
6SN112
j
–1AB00–0AA
V
2x15 A
X
X
X
X
M5
0,7...0,8
6SN1123–1AB00–0HA
V
2x8 A
X
X
X
X
M5
0,7...0,8
Key
Terminal area for flexible cable with end sleeves (with or without plastic collars)
Terminal area for flexible cables with terminal pin
X
IP20 is guaranteed when correctly used, e.g. insulated pin–type cable lugs
1) Size of the screw for the protective conductor connection
2) Tightening torque of the terminals or connectors
!
Warning
The internal overload monitoring function of the power modules only protects
the cable if this is dimensioned/selected corresponding to the power module
currents. If smaller cross–sections are selected, then the user must ensure the
appropriate level of cable protection, e.g. by suitably setting the control
parameters.
Note
For UL certification, only use copper cables that have been appropriately
dimensioned/selected for the operating temperature
w
60
_
C.