6.2 Interface overview
6-151
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 6-2
Interface overview, 5 kW UI modules, continued
Term.
No.
Max. cross–section
6)
Typ. voltage/limit values
Type
1)
Function
Desig-
nation
111
213
X161
X161
Signaling contact
Line contactor
I
NC
1–ph. 250 V AC/50 V DC/2 A
7)
17 V DC/3 mA min
1.5 mm
2
1.5 mm
2
max. cable length,
30 m
9
2)4)
112
48
NS1
NS2
15
X141B
X141B
X141B
X141B
X141B
X141B
FR+
Setup/normal operation
Contactor control
M
Coil contact for
line supply, pre–charging
contactor
O
I
I
O
I
O
+24 V
+13 V...30 V/R
E
= 1.5 k
Ω
+13 V...30 V/R
E
= 1.5 k
Ω
+24 V
0/+24 V
0 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1) I = input; O = output; NC = NC contact; NO = NO contact
2) Term. 19 is the reference ground (connected through 10 k
W
to the general reference ground X131 inside the module)
Terminal 15 must not be connected to PE, to terminal 19 or to external voltage sources
Terminal 19 can be connected to X131.
The terminal may be used exclusively for enabling the associated drive group.
3) The grounding clip is used to ground the DC link M busbar through 100 k
Ω
(must be closed;
the grounding clip must be opened if the system is subject to a high–voltage test).
4) max. current load of terminal 9 – terminal 19
1 A
Notice: For the 5 kW, there are no terminals 7, 45, 44 and 10.
5) RESET = resets the fault memory, edge–triggered for the complete drive group
(terminal ”R”
Term. 19 = RESET)
6) For UL certification
:
only use copper cables dimensioned for an operating temperature
60
7) In accordance with EN 60204–1 (machine safety),
control transformers must be used for AC control voltages.
Notice
There are no 7, 45, 44 and 10 terminals for the 5 kW UI module.