6
05.01
6.3 Function overview and settings
6-164
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
This function is only applicable in conjunction with I/R modules
Order No.: 6SN114
–1B
0
–0
A1
OFF: regulated infeed active (default setting)
ON:
Unregulated operation in the infeed direction V
DC link
= V
line
1.35
Notice:
For unregulated operation of the I/R units with V
line
= 400 V/415 V, the power
must be reduced (derated) as specified in Section 5.5.
OFF: Squarewave current operation (current with a squarewave shape is
drawn from the line supply)
ON:
This function is only applicable in conjunction with I/R modules with
Order No.: 6SN114
–1B
0
–0
A1
sinusoidal current operation (sinusoidal current is taken from the line supply)
Combinations of the components:
Table 6-6
Combinations (regenerative feedback into the line supply)
I/R
16 kW
I/R
36 kW
I/R
55 kW
I/R
80 kW
I/R
120 kW
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
6SN1145–
1BA01–0BA
6SN1145–
1BA02–0CA
6SN1145–
1BA01–0DA
6SN1145–
1BB00–0EA
6SN1145–
1BB00–0FA
For external
Cooling:
For external
cooling:
For external
cooling:
For external
Cooling:
For external
cooling:
6SN1146–
1BB01–0BA
6SN1146–
1BB02–0CA
6SN1146–
1BB00–0DA
6SN1146–
1BB00–0EA
6SN1146–
1BB00–0FA
HFD reactor
16 kW
HFD reactor
36 kW
HFD reactor
55 kW
HFD reactor
80 kW
HFD reactor
120 kW
6SL3000–
0DE21–6AA
6SL3000–
0DE23–6AA
6SL3000–
0DE25–5AA
6SL3000–
0DE28–0AA
6SL3000–
0DE31–2AA
Wideband
Line Filter
16 kW
Wideband
Line Filter
36 kW
Wideband
Line Filter
55 kW
Wideband
Line Filter
80 kW
Wideband
Line Filter
120 kW
6SL3000–
0BE21–6AA
6SL3000–
0BE23–6AA
6SL3000–
0BE25–5AA
6SL3000–
0BE28–0AA
6SL3000–
0BE31–2AA
Basic
Line Filter
16 kW
Basic
Line Filter
36 kW
Basic
Line Filter
55 kW
-
-
6SL3000–
0BE21–6DA
6SL3000–
0BE23–6DA
6SL3000–
0BE25–5DA
-
-
Switch S1.5
Switch S1.6
6 Infeed Modules