6.4 Technical data
6-167
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 6-9
Technical specifications, I/R modules
Internal cooling
External cooling
Hose cooling
6SN11 45-
6SN11 46-
6SN11 45-
1BA0
-0BA
1BB0
-0BA
-
1BA0
-0CA
1BB0
-0CA
-
1BA0
-0DA
1BB0
-0DA
1BB0
-0DA
1BB0
-0EA
1BB0
-0EA
1BB0
-0EA
1BB0
-0FA
1BB0
-0FA
1BB0
-0FA
Infeed/regenerative
feedback
Rated power (S1)
S6 power
Peak power (400 V)
kW
kW
kW
16
21
35
36
47
70
55
71
91
2)
80
104
131
2)
120
156
175
Sinusoidal operation in-
put currents (AC
RMS
)
Use for dimensioning the installation, not for calculating the power!
Rated current (400 V)
A
rms
27
60.5
92.5
134
202
Squarewave operation
input currents (AC
RMS
)
Use for dimensioning the installation, not for calculating the power!
Rated current (400 V)
A
rms
30
67
102
149
223
Use for dimensioning the installation, not for calculating the power! (calculated)
Rated current (400 V)
unregulated operation
A
rms
33
74
114
165
248
Connection data
Voltage (power)
V
rms
refer to Chapter C.1.3, Table 3.5
Voltage (electronics)
V
refer to Chapter C.1.3, Table 3.5
Power supply
V
rms
At the DC link with 600/625/680 V DC or supplied in parallel, AC and DC con-
nection or DC connection only.
Frequency
Hz
50 to 60
10%
Connection cross–sec-
tion
mm
2
Max. 16
Max. 50
Max. 95
Max. 95
Max. 150
Output voltage
V
regulated: 600/625; unregulated: 490...680 (line supply–dependent)
Module width
mm
100
200
300
300
300
Type of cooling
Internal cooling
(volumetric flow rate)
m
3
/h
Fan
56
Fan
112
Fan
112
Built–on fan
400
3)
Built–on fan
1)
400
3)
(volumetric flow rate)
External cooling
1)
Hose cooling
m /h
56
Fan
–
112
Fan
–
Mounting frame (Bestell-Nr. 6SN1162–
0BA04–0EA
) with fan assembly and built–on
fan (6SN1162–0BA02–0AA2
Hose cooling
–
–
Kit for hose cooling with fan
Losses
Internal cooling
External cooling
Hose cooling
W
W (int./ext.)
W (int./ext.)
320
50/270
–
585
50/535
–
745
115/630
115/630
1280
190/1090
190/1090
1950
290/1660
290/1660
Efficiency
η
0.97
0.97
0.97
0.97
0.97
Weight
Internal cooling
External cooling
Hose cooling
kg
kg
kg
10.5
10.5
–
15.5
15.5
–
26
26
26
26
26
26
29
29
29
1) For a module width of 300 mm with external cooling, mounting frames are required that must be ordered separately.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be ordered separately! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown in this
Configuration Manual.
2) External power supply for main contactor control required (see Chapter 6.2.5).
3) ) Must be separately ordered: Mounted fan, 6SN1162–0BA02–0AA2
4) See the diagram with pipe cooling in Chapter 2.7.1, Fig. 2-7
6 Infeed Modules