6
05.01
6.4 Technical data
6-168
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Table 6-10
Technical data, UI modules
Heat dissipation
Heat dissipation
Hose cooling
6SN11 45-
6SN11 46-
6SN11 45-
–
1AB00–0BA
(INT./EXT.)
–
1AA01–0AA
(INT./EXT.)
–
–
1AA00–0CA
(INT.)
1AB00–0CA
(EXT.)
–
Infeed/regenerative
feedback
Rated power (S1)
S6 power
Peak power (400 V)
kW
kW
kW
5
6.5
10
10
13
25
28
36
50
Input currents (
(AC
RMS
)
Use for dimensioning the installation, not for calculating the power!
Rated current (400 V)
12
24
68
Built-in pulsed resi-
stor
Continuous power/
Peak power
kW
0,2/10
0,3/25
–
Energy consumption,
max:
kWs
E = 13,5
E = 7,5
–
Connection data
Voltage (power)
V
refer to Chapter C.1.3, Table 3.5
Voltage (electronics)
V
refer to Chapter C.1.3, Table 3.5
Power supply
V
At DC link with 600/625/680 V DC or parallel infeed, AC and DC connection
Frequency
Hz
50 to 60
10%
Connection cross–
section, max.
mm
2
6
16
50
Output voltage
V
0...490...680 depending on the line supply voltage
Output frequency
Hz
0...1400 depending on the control unit
Module width
mm
50
100
200
Type of cooling
Internal cooling
Non–ventilated
Universal cooling
Internal separately–
driven fan
Internal cooling
External cooling
Hose cooling
Non–ventilated
Non–ventilated
–
Universal cooling
internal/external
–
Internal separately–
driven fan
Integrated third–party
fan (volumetric flow,
External cooling
Hose cooling
Non–ventilated
–
internal/external
–
Integrated third–party
fan (volumetric flow,
both 42 m
3
/hr)
Losses
Internal cooling
External cooling
Hose cooling
W
W (int./ext.)
W (int./ext.)
270
270/–
–
450
120/330
–
250
90/160
–
Efficiency
η
0.98
0.98
0.98
Weight
Internal cooling
External cooling
Hose cooling
kg
kg
kg
6.5
6.5
–
9.5
9.5
–
15.5
15.5
–
Note
Temperature derating, see Chapter 5.4.2.
Installation altitude derating, see Chapter 5.4.3.
6 Infeed Modules
05.08
02.12