6
05.01
6.5 HFD reactor
6-177
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
U/L1/C/L+
HFD reactor
Order No., refer to Table 6-12
HFD reactor, terminal connection
1)
PE
3
2
1
Cable connection to the resistor.
The cable length of 5 m may be
decreased but not increased.
ÏÏ
ÏÏ
Shield contact
gn/ye
PE
W/L3/D/L–
ÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
V/L2
bk
bk
bk
HFD resistor,
example 800 W
Connecting the cable
to the HFD reactor
1) Jumper, 2–3–PE for potential connection (EMC)
is provided as standard
1
2
3
PE
1)
Resistance
U/L1/C/L+
V/L2
W/L3/D/L–
PE
Connection circuit, 300 W resistor
Note:
It is not permissible to route cables in or close to
the warm airflow of the damping resistor!
Mounting position:
Arbitrary mounting position but consider the
heat dissipation, if necessary, provide a ”Hot
surface” warning notice!
Cable labeling
Example, 800 W resistor
1
1)
U/L1/C/L+
V/L2
W/L3/D/L–
PE
Connection circuit, 800/1500 W resistor
2
3
PE
Resistance
Fig. 6-14
Wiring, HFD reactor and damping resistor
HFD reactor con-
nection
6 Infeed Modules
02.12