6
05.01
6.6 Monitoring module
6-179
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
6.6
Monitoring module
6.6.1
Integration into the overall system
The monitoring module contains an electronic power supply and central moni-
toring functions, which are required to operate the drive modules.
6.6.2
Technical data (supplement to the general technical data)
Table 6-16
Technical data, monitoring module
Power loss
70 W
Rated supply voltage
3–ph. 400 V – 10% up to 480 V AC + 6%
Alternatively, rated supply voltage
DC link
600/625/680 V DC
Current consumption
for 3–ph. 400 V AC: approx. 600 mA
Type of cooling
Natural ventilation
Weight
approx. 5 kg
Assessment factor for the electronic points
(EP)
Max. 8
Assessment factor for the gating points (AP)
Max. 17
The cross–section that can be connected to
the P600, N600, X131 terminal block
Max 10 mm
2
for cables with
conductor end sleeves
Max 16 mm
2
for cables with
pin–type cable lug
Reader’s note
For an overview of the interfaces, refer to Section 6.2.1, Table 6-1 in the column
”Terminals used” under monitoring module.
For operation of the monitoring module only on the DC link, without AC power
supply, 1000
μ
F per monitoring module must be observed for the loading limit of
the line supply.
This capacity is not included in the calculation of the permitted number of
pulsed resistors, because they are de–coupled using diodes.
6 Infeed Modules
02.12