6.7 DC link options
6-194
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
6.7.3
External pulsed resistors
With externally attached pulsed resistors, the power loss of the resistor that oc-
curs during braking accumulates outside the control cabinet and, thus, does not
place a thermal load on the control cabinet.
The external pulsed resistors are generally required for the 28 kW UI module.
Depending on the power requirement, up to two equal pulsed resistors can be
connected in the case of the 28 kW UI module. The protection function is para-
meterized via the connecting terminals.
Table 6-23
Technical specifications
Data
External pulsed resistor
0.3/25 kW (15
Ω
)
Plus 1.5/25 kW (15
Ω
)
Order number
6SN1113–1AA00–0DA0
(only for 28 kW UI module/
HFD)
6SL3100–1BE22–5AA0
Degree of protection acc. to
DIN EN 60529 (IEC 60529)
IP54
IP20
Weight [kg]
3.4
5.6
Type of cooling
Natural ventilation
Natural ventilation
Dimensions (W x H x D) [mm]
80 x 210 x 53
193 x 410 x 240
including the connecting cable
[m]
3
5
Mounting
position
Note:
Carefully note the mounting position, base mounting is possible.
When mounting the pulsed resistor it must be carefully ensured that it is not located
in the cooling airflow of the drive group and there is sufficient clearance to the cable
ducts.
External PR 0.3/25 kW
External PR Plus 1.5/25 kW
Connecting cable
Connecting cable
Fig. 6-22
Pulsed resistor, external