7.4 Line filters for I/R and UI modules
7-234
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
7.4.3
Line Filter
The line filters for UI modules attenuate frequencies in the range from 150 kHz
up to 30 MHz. In conjunction with the consequential implementation of the sys-
tem configuration according to the Configuration Manual and the EMC installa-
tion guideline for SIMODRIVE, SINUMERIK, SINAMICS S 120, when applying
the installation guideline, the limit values at the installation location can be at-
tained according to the EC directive EMC. The precondition is that the user
takes into account the specific EMC guidelines at the installation location that
may possibly apply and makes a final check. From the line filter, total cable
lengths up to 500 m are possible!
Table 7-15
Assigning wideband line filters to the UI modules
UI module
5/10 kW
UI module
10/25 kW
UI module
28/50 kW
Filter components
Line filter, 5 kW
Line filter, 10 kW
Line filter, 36 kW
Rated AC current
16 A
25 A
65 A
Order number
6SN1111–0AA01–1BA
3)
6SN1111–0AA01–1AA
3)
6SN1111–0AA01–1CA
3)
Supply voltage
3–ph. 380 V – 10% ... 3–ph. 480 V AC + 10% (TN line supply)
1)
; 50...60 Hz
10%
Mounting position
Arbitrary (only for UI modules)
Dimensions (W x H x D),
approx.
156 x 193 x 81
156 x 281 x 91
171 x 261 x 141
Module width
Refer to dimension drawings, Chapter 12
Weight, filter
3.8 kg
5.7 kg
12.5 kg
Power loss
20 W
20 W
25 W
Connection
4 mm
2
/1.5 Nm
PE, M6 studs/3 Nm
10 mm
2
/1.5 Nm
PE, M6 studs/3 Nm
50 mm
2
/6 Nm
PE, M10 studs
Terminals
Line supply connection
(line)
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
Terminals
Load connection (load)
U, V, W
U, V, W
U, V, W
I
rated
fuse
2)
16 A
25 A
80 A
Permissible
ambient temperature
Operation
[
°
C]
Storage/transport
[
°
C]
0 ... +40; m55 at 0.6
•
P
rated
of the UI module
–25 ... +70
Cooler
Natural ventilation
Degree of protection to EN
60529 (IEC 60529)
IP20
DIN EN 61800-3 (IEC
61800-3)/VDE 0160-103 ra-
dio interference suppres-
sion
Limit value Class C 2.
1) The permissible supply voltage of the system depends on the infeed module used.
2) The fuse used must have this rated current. Recommendations for the fuses, refer to Table 7-6.
3) Last position of the Order No.
1
Description
7 Line Supply Connection
02.12